Klima Non-Insulated Ring Lug 6 mm²
Ring lug crimp terminal for 4 to 6 mm² conductors.
Klima Terminal Crimps · Model KTR-L60
About this crimp terminal
This copper ring lug takes conductors from 4 to 6 mm² on an M6 stud. It has no insulating sleeve, which makes it the right terminal for heavy power connections where the insulation is added separately, for example a heat-shrink sleeve or a terminal cover that is part of the equipment. It is the largest crimp terminal in the Klima range and the one used on bigger contactors, earth bars and power studs.
A bare lug must never be left uncovered. After crimping and fitting, slide a heat-shrink sleeve over the barrel and shrink it, or use a terminal boot, so that no live copper is exposed. The crimp itself must be made with a proper crimping tool, because pliers cannot compress the barrel enough at this size; use a tool and die made for the conductor size.
Specifications
| Specification | Value |
|---|---|
| Model | KTR-L60 |
| Type | Ring lug |
| Wire size | 4 to 6 mm² |
| Stud size | M6 mm |
| Insulation | None |
| Colour code | Uninsulated |
| Material | Copper |
Where it fits
- Power connections from 4 to 6 mm² cable to M6 studs
- Earth bars and bonding studs on plant equipment
- Large contactors, isolators and distribution blocks with stud terminals
- Installations where the heat-shrink sleeve or boot is fitted separately
Fitting and checking
Slide the heat-shrink sleeve onto the cable before the lug, because it cannot be fitted afterwards. Strip the cable to the length of the barrel, crimp with a suitable tool and die, then check by pulling on the lug. Fit the lug to the stud with the washers and nut the equipment requires, tighten to the torque, shrink the sleeve over the barrel and, after the first weeks of service, check the torque again.
Compared with the other terminal crimps
This model is one of 6 in Klima Terminal Crimps; what changes from one to the next is type, wire size and stud size. Every model in the family has the same material (Copper), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Type | Ring lug | Ring / Spade / Quick-connect / Pin and 1 more |
| Wire size | 4 to 6 mm² | 0.5 to 1.5 / 1.5 to 2.5 / 4 to 6 |
| Stud size | M6 mm | M4 / M5 / M6 |
| Insulation | None | PVC / None |
| Colour code | Uninsulated | Red / Blue / Uninsulated |
The closest alternative in the range is Klima Insulated Ring Terminal 1.5 mm², which shares 1 of the 7 listed specifications and differs in type, wire size and stud size. Quote the model code KTR-L60 when you enquire.
Questions
Why is this lug uninsulated?
Heavier power connections are often insulated with heat-shrink or a boot, which gives a more durable finish than a thin plastic sleeve and allows inspection of the crimp.
Can I crimp a 6 mm² lug with a small tool?
Use a tool and die sized for 4 to 6 mm² conductors. One made for small terminals cannot compress the barrel properly and leaves a loose connection.
Selection, care and fault-finding notes for the whole family are on the Klima Terminal Crimps page, and the contact page takes enquiries with the model code KTR-L60. For background reading, see the guide How to choose a run capacitor for an air conditioner.