HVAC Parts that keep Air Conditioning and Refrigeration running
Klima Industries makes capacitors, contactors, cables, copper tube, filter driers, controls and accessories for air conditioning and refrigeration. Choose a product family, check the specification and send an enquiry from anywhere in the world.
18 product families, grouped by the job they do
Electrical parts start and protect motors, refrigeration parts keep the circuit tight, controls decide when the air conditioners and refrigeration system runs, and accessories finish the installation.
Electrical components
Parts that start, switch, power and connect motors and controls.
- Klima Capacitors Run and dual-run capacitors for compressors, fan motors and blowers.
- Klima Contactors AC contactors for compressors, condenser fans and plant control.
- Klima Cables (3 & 4 Core) 3-core and 4-core flexible cables for air conditioner power and control wiring.
- Klima Terminal Crimps Crimp terminals and lugs for secure, low-resistance electrical connections.
- Klima Transformer for HVAC Control transformers that step mains voltage down to 24 V for HVAC controls.
Refrigeration circuit parts
Parts that carry, clean and join the refrigerant circuit.
- Klima Copper Coils & Tubes Refrigeration-grade copper tube in coils and straight lengths, sized by diameter and wall thickness.
- Klima Drier Core 48-DC Replaceable drier core that removes moisture and acid from refrigerant circuits.
- Klima Filter Driers Sealed filter driers for liquid and suction lines in AC and refrigeration.
- Klima Flux Powder (100 g & 250 g) Brazing flux powder in 100 g and 250 g tubs for clean, strong copper joints.
- Klima Map Gas (Brazing & Welding) High-heat fuel gas cylinders for brazing and welding refrigerant lines.
Controls and measurement
Parts that sense, set, protect and measure.
- Klima Delay on Make Timer Time delay relays that stop compressors from short cycling.
- Klima Thermostats WiFi, fan coil, fridge and room thermostats for cooling and heating control.
- Klima Pressure Switches (High & Low) High- and low-pressure switches that protect compressors and refrigerant circuits.
- Klima Temperature Controllers Digital temperature controllers for cold rooms, display cabinets and process equipment.
- Klima Thermometers for HVAC Digital, dial and pipe-clamp thermometers for HVAC commissioning and service.
Accessories and consumables
Parts that finish an installation and keep it tidy and safe.
- Klima Condensate Pump Mini condensate pumps for AC units that cannot drain by gravity.
- Klima PVC Tapes PVC insulating and pipe-wrapping tapes for AC wiring and refrigerant line sets.
- Klima Thermostat Guards Locking covers that protect wall thermostats from tampering and knocks.
Popular models
Quote the model code when you enquire and the right part is found first time.
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Core Flexible Cable 1.5 mm² Cores: 3, Conductor size: 1.5 mm², Insulation: PVC
- Klima Mini Condensate Pump Max lift: 5 m, Flow rate: 12 L/h, Tank volume: 0.5 L
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Delay on Make Timer, Fixed, 24 V AC/DC Supply voltage: 24 V AC/DC, Delay range: 3 min fixed, Contact rating: 5 A
- Klima Drier Core 48-DC Shell series: 48 series, Desiccant: Molecular sieve, Refrigerants: R22, R134a, R404A, R407C, R410A
- Klima Filter Drier 1/4 in Flare Type: Liquid line, Connection size: 1/4 in, Connection style: Flare
- Klima Brazing Flux Powder 100 g Pack size: 100 g, Type: Brazing flux powder, Typical use: Copper, brass and steel with silver-bearing rods
- Klima WiFi Room Thermostat Type: WiFi room thermostat, Temperature range: 5 to 35 °C, Supply: 230 V AC
- Klima Map Gas Cylinder 400 g Cylinder size: 400 g, Use: Brazing and welding, Valve thread: Screw-on torch thread
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
Supply notes for every country, city and area
Mains voltage, climate, typical buildings and the jobs each product family is chosen for, written for the place you are working in.
- Afghanistan
- Aland Islands
- Albania
- Algeria
- American Samoa
- Andorra
- Angola
- Anguilla
- Antigua and Barbuda
- Argentina
- Armenia
- Aruba
- Australia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bermuda
- Bhutan
- Bolivia
- Bonaire, Saint Eustatius and Saba
- Bosnia and Herzegovina
- Botswana
- Brazil
- British Virgin Islands
- Brunei
- Bulgaria
- Burkina Faso
- Burundi
- Cambodia
- Cameroon
- Canada
- Cape Verde
- Cayman Islands
- Central African Republic
- Chad
- Chile
- China
- Christmas Island
- Cocos Islands
- Colombia
- Comoros
- Cook Islands
- Costa Rica
- Croatia
- Cuba
- Curacao
- Cyprus
- Czech Republic
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- DR Congo
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Eswatini
- Ethiopia
- Falkland Islands
- Faroe Islands
- Fiji
- Finland
- France
- French Guiana
- French Polynesia
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Gibraltar
- Greece
- Greenland
- Grenada
- Guadeloupe
- Guam
- Guatemala
- Guernsey
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Honduras
- Hong Kong
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Isle of Man
- Israel
- Italy
- Ivory Coast
- Jamaica
- Japan
- Jersey
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macau
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Martinique
- Mauritania
- Mauritius
- Mayotte
- Mexico
- Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Montserrat
- Morocco
- Mozambique
- Myanmar
- Namibia
- Nauru
- Nepal
- New Caledonia
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Niue
- Norfolk Island
- North Korea
- North Macedonia
- Northern Mariana Islands
- Norway
- Oman
- Pakistan
- Palau
- Palestine
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Pitcairn
- Poland
- Portugal
- Puerto Rico
- Qatar
- Republic of the Congo
- Reunion
- Romania
- Russia
- Rwanda
- Saint Barthelemy
- Saint Helena
- Saint Martin
- Saint Pierre and Miquelon
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Sint Maarten
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Korea
- South Sudan
- Spain
- Sri Lanka
- St Kitts and Nevis
- St Lucia
- St Vincent and the Grenadines
- Sudan
- Suriname
- Svalbard and Jan Mayen
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- The Netherlands
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Turks and Caicos Islands
- Tuvalu
- U.S. Virgin Islands
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Vatican City
- Venezuela
- Vietnam
- Wallis and Futuna
- Western Sahara
- Yemen
- Zambia
- Zimbabwe
From the knowledge hub
Selection, sizing and fitting notes written for installers and buyers.
- How to choose a run capacitor for an air conditioner
- Contactor sizing for compressors: poles, current and coil voltage
- Brazing refrigerant pipe: flux, filler rods and map gas
Parts for every stage of an air conditioning or refrigeration job
Every air conditioning and refrigeration system is built from the same small set of working parts: motors that need capacitors and contactors, refrigerant circuits that need clean copper, driers and brazing consumables, and controls that need thermostats, pressure switches and sensors. Klima Industries makes 186 models in 18 product families across these groups, so an installer, a service company or a wholesaler can source a whole job from one catalogue.
The range is organised the way technicians think about a unit. Electrical parts keep the compressor and fans running. Refrigeration circuit parts keep the refrigerant clean, dry and leak-tight. Controls and measurement parts hold the set point and protect the system. Accessories and consumables finish the installation neatly and safely. Each model page carries a specification table and a comparison with the other models in its family, so a part can be matched to a nameplate without guesswork.
How to choose the right part
Start with the part you are replacing. Its nameplate or label carries the values that matter: capacitance and voltage on a capacitor, poles, current and coil voltage on a contactor, pressure range and reset type on a pressure switch, outside diameter and wall thickness on copper tube. Match those values first. Then check the supply voltage and frequency, the refrigerant where the part is under pressure, and the physical fit: terminals, connection size and mounting.
The knowledge hub has a guide for each step. How to choose a run capacitor and contactor sizing cover the electrical side. Filter driers and drier cores, brazing and pressure switches cover the refrigerant circuit, and superheat and subcooling explains which thermometer to use for a charge check.
Where the parts are used
- Split and multi-split air conditioners: run capacitors, contactors, interconnecting cable, copper line sets, filter driers, and PVC tape to wrap the line set.
- Packaged units and chillers: three-pole contactors, pressure switches, delay on make timers, control transformers and thermostats.
- Fan coil and cassette units: fan coil thermostats, and condensate pumps where a unit cannot drain by gravity.
- Cold rooms, display cabinets and freezers: temperature controllers, capillary fridge and freezer thermostats, drier cores, and thermometers for service checks.
- Workshop and site work: brazing flux, map gas, crimp terminals and insulating tape.
Supply information for every region
Climate, mains supply, building types and local rules all affect which part is the right one. The locations directory covers 242 countries, 4,138 cities and 1,480 areas. Each place has supply pages for the product families, explaining the ambient conditions, the supply voltage and frequency, the equipment found there and the jobs that call for each family. A hot, dusty coastal city and a cool inland capital get different notes, because the parts that last in each are different.
Trade, project and export enquiries
Contractors, wholesalers and equipment builders can ask for trade terms on the distributors page. The shipping page lists what to include when goods are going abroad, and the contact page takes a model code, a quantity and a destination. The FAQ answers the questions that come up most often, including how to read a Klima model code.