Klima Contactors
A contactor is an electrically operated switch. A small control signal from the thermostat or controller energises its coil, and the main contacts close to feed full line current to the compressor or condenser fan. Because the contacts make and break high currents hundreds of times a day, they wear, and pitted contacts are one of the most common causes of intermittent cooling failures.
Klima Contactors are available in 1-, 2- and 3-pole versions with 24 V, 110/120 V and 220/240 V coils. Ratings are given for motor (inductive) duty so that sizing matches the way the contactor is really used, and the model list shows dimensions so you can check fit inside existing control boxes.
Klima Contactors switch the compressor and fan loads in air conditioning and refrigeration equipment. Models are listed by pole count, rated current and coil voltage so you can match the contactor to both the motor and the control circuit.
Models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
Related products
Supply notes by country
How contactors are chosen and used in each country, with notes for its cities.
- Afghanistan
- Aland Islands
- Albania
- Algeria
- American Samoa
- Andorra
- Angola
- Anguilla
- Antigua and Barbuda
- Argentina
- Armenia
- Aruba
- Australia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bermuda
- Bhutan
- Bolivia
- Bonaire, Saint Eustatius and Saba
- Bosnia and Herzegovina
- Botswana
- Brazil
- British Virgin Islands
- Brunei
- Bulgaria
- Burkina Faso
- Burundi
- Cambodia
- Cameroon
- Canada
- Cape Verde
- Cayman Islands
- Central African Republic
- Chad
- Chile
- China
- Christmas Island
- Cocos Islands
- Colombia
- Comoros
- Cook Islands
- Costa Rica
- Croatia
- Cuba
- Curacao
- Cyprus
- Czech Republic
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- DR Congo
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Eswatini
- Ethiopia
- Falkland Islands
- Faroe Islands
- Fiji
- Finland
- France
- French Guiana
- French Polynesia
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Gibraltar
- Greece
- Greenland
- Grenada
- Guadeloupe
- Guam
- Guatemala
- Guernsey
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Honduras
- Hong Kong
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Isle of Man
- Israel
- Italy
- Ivory Coast
- Jamaica
- Japan
- Jersey
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macau
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Martinique
- Mauritania
- Mauritius
- Mayotte
- Mexico
- Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Montserrat
- Morocco
- Mozambique
- Myanmar
- Namibia
- Nauru
- Nepal
- New Caledonia
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Niue
- Norfolk Island
- North Korea
- North Macedonia
- Northern Mariana Islands
- Norway
- Oman
- Pakistan
- Palau
- Palestine
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Pitcairn
- Poland
- Portugal
- Puerto Rico
- Qatar
- Republic of the Congo
- Reunion
- Romania
- Russia
- Rwanda
- Saint Barthelemy
- Saint Helena
- Saint Martin
- Saint Pierre and Miquelon
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Sint Maarten
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Korea
- South Sudan
- Spain
- Sri Lanka
- St Kitts and Nevis
- St Lucia
- St Vincent and the Grenadines
- Sudan
- Suriname
- Svalbard and Jan Mayen
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- The Netherlands
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Turks and Caicos Islands
- Tuvalu
- U.S. Virgin Islands
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Vatican City
- Venezuela
- Vietnam
- Wallis and Futuna
- Western Sahara
- Yemen
- Zambia
- Zimbabwe
Key features
- Pole configurations. 1-, 2- and 3-pole models cover single-phase condensing units and three-phase compressors alike.
- Coil voltage options. 24 V control circuits as well as mains-voltage coils for direct switching.
- Motor-duty current ratings. Ratings are quoted for inductive loads, not just resistive load.
- Auxiliary contact options. Models with normally-open and normally-closed auxiliaries for feedback and interlocks.
- Panel-friendly bodies. Dimensions and mounting details are listed per model for like-for-like replacement.
Where contactors are used
- Compressor control in split and packaged air conditioners
- Condenser fan switching
- Walk-in cold rooms and refrigerated display cases
- Chiller and air handling unit starter panels
- Heat pump defrost and reversing controls
- Pump and ventilation motor control
- Hotel fan coil and VRF outdoor unit panels
- Heater banks and electric reheat
- Lighting and general power switching in plant rooms
How to choose contactors
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
- Pick the right pole count: 2-pole for single-phase units where both lines must break, 3-pole for three-phase compressors.
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Check whether the control logic needs auxiliary NO or NC contacts for feedback.
Care and maintenance
- Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.
- Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
Common faults
- A buzzing or chattering contactor
- A compressor that will not start although the thermostat is calling for cooling
- Burnt or welded contacts that keep the unit running when switched off
Questions about contactors
What does the number of poles mean?
A pole is one switched circuit. A 2-pole contactor breaks both line wires of a single-phase supply, while a 3-pole contactor breaks all three phases of a three-phase supply.
What coil voltage should I choose?
Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.
Can I replace a contactor with a higher amp rating?
Yes. A higher rated current is safe and usually longer lasting, provided the coil voltage, pole count and physical size suit the installation.
Why does my contactor buzz?
Buzzing usually means low coil voltage, a dirty or worn magnetic core or a loose connection. Measure the voltage at the coil while the unit is calling for cooling.
Is a contactor the same as a relay?
They work the same way, but contactors are built for higher currents and repeated switching of motor loads, whereas relays handle small control currents.
How often should contactors be replaced?
There is no fixed interval. Replace them when the contacts show pitting or heat discolouration, or at the first sign of intermittent starting. Frequent cycling shortens life.