Klima 3-Pole Contactor 40 A, 230 V Coil
3-pole contactor rated 40 A with a 230 V AC coil for compressor and fan switching.
Klima Contactors ยท Model KCT-3P40-230
About this contactor
At 40 A with three poles and a 230 V AC coil, this contactor is for larger compressors and for loads that group several motors on one switch. A higher rating gives more margin for the starting current of a bigger compressor and more contact life on a unit that cycles often. The line-voltage coil lets a mains-voltage controller or thermostat operate it directly, and the contactor mounts on a screw plate or DIN rail.
It is also suitable for resistive loads such as electric reheat or defrost stages, though the rating that applies to a heater is the resistive one. Make sure of this on the datasheet, since the same contactor has a lower current rating for motor duty than for heating loads. In every case, add an overload device that suits the motor and the conductors.
Specifications
| Specification | Value |
|---|---|
| Model | KCT-3P40-230 |
| Poles | 3 |
| Rated current | 40 A |
| Coil voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Mounting | Screw or DIN rail |
Where it fits
- Larger three-phase compressors in packaged units and chillers
- Banks of condenser fans and ventilation motors on one contactor
- Electric heater stages in ducted and process air systems
- Pump sets and booster sets in HVAC plant rooms
Fitting and checking
Strip the conductor to the length shown on the terminal and torque the screws; stranded cables are best fitted with ferrules. Run the load and take a thermal image or touch-test the terminals with the supply isolated afterwards; a warm connection is a loose one. Make a note of the contact condition at each service. Pitted contacts are normal after years of use, but a contactor that welds shut has been overloaded and needs replacing at once.
Compared with the other contactors
This model is one of 7 in Klima Contactors; what changes from one to the next is poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Poles | 3 | 2 to 3 |
| Rated current | 40 A | 25 to 63 A |
| Coil voltage | 230 V AC | 24 V AC / 230 V AC |
Ordered by rated current, this model is number 6 of 7: the next step down is Klima 3-Pole Contactor 32 A, 230 V Coil (32 A) and the next step up is Klima 3-Pole Contactor 63 A, 230 V Coil (63 A). Quote the model code KCT-3P40-230 when you enquire so that the right size is supplied.
Questions
Can I use the 40 A model in place of a 32 A one?
Yes, if the coil voltage matches and it fits the mounting; the larger rating gives more margin. The wiring must still be correct for the load.
How do I know the contactor is wearing out?
Look for pitting, blackening or a weld on the contacts, a chattering coil, or heat marks on the terminals. Any of these is a reason to replace it before the next hot season.
Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-3P40-230. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.