Klima 3-Pole Contactor 63 A, 230 V Coil
3-pole contactor rated 63 A with a 230 V AC coil for compressor and fan switching.
Klima Contactors ยท Model KCT-3P63-230
About this contactor
The 63 A contactor is the largest in the Klima range: three poles, a 230 V AC coil and a screw or DIN-rail mount. It is meant for large compressors, big fan and pump motors, and for use as the main contactor of a control panel that feeds several loads. At this rating the terminals accept heavy cable, and the contact system is designed to carry a high current continuously.
A contactor this size draws a considerable pull-in current through its coil, so the control supply must be stiff. A weak supply or a long, thin control cable gives slow, noisy closing, which erodes the contacts. Where a contactor of this rating is used as a main contactor, fit upstream protection (a circuit breaker or fuses) matched to the cable, because the contactor switches current but does not interrupt a short circuit.
Specifications
| Specification | Value |
|---|---|
| Model | KCT-3P63-230 |
| Poles | 3 |
| Rated current | 63 A |
| Coil voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Mounting | Screw or DIN rail |
Where it fits
- Large three-phase compressors in chillers and big condensing units
- Main contactor for a plant panel feeding several smaller loads
- Large fan and pump motors in HVAC plant rooms
- Electric heater banks for process and ducted heating
Fitting and checking
Use cable and lugs sized for the load, and tighten to the manufacturer's torque; at 63 A a poor connection can dissipate enough heat to damage the housing. Leave space around the contactor so that heat can escape and vibration from a nearby compressor does not shake it. After commissioning, measure the voltage drop across each closed pole under load: a significant reading points to dirty or worn contacts.
Compared with the other contactors
The 7 models in Klima Contactors differ mainly in poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Poles | 3 | 2 to 3 |
| Rated current | 63 A | 25 to 63 A |
| Coil voltage | 230 V AC | 24 V AC / 230 V AC |
This is the largest model in the range by rated current. The next step down is Klima 3-Pole Contactor 40 A, 230 V Coil (40 A). Quote the model code KCT-3P63-230 when you enquire so that the right size is supplied.
Questions
Is the 63 A rating for motor loads or resistive loads?
Check the utilisation category in the datasheet; motor duty is lower than the resistive rating. Select the contactor for the motor's running and starting current.
Can this contactor stop a short circuit?
No. It is a switching device, not a protective one. Use a circuit breaker or fuses upstream, sized for the cable and the load.
Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-3P63-230. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.