Knowledge hub
Short, practical guides for installers, technicians and buyers. Each one explains how a part works, how to choose it and what usually goes wrong, with links to the matching product family.
- How to choose a run capacitor for an air conditioner Match capacitance, voltage and terminals to the nameplate, and learn how to tell when a capacitor has weakened.
- Contactor sizing for compressors: poles, current and coil voltage How to pick a contactor for a compressor or fan: pole count, motor-duty current rating and coil voltage explained.
- Brazing refrigerant pipe: flux, filler rods and map gas A practical guide to brazing copper refrigerant lines: choosing filler rod and flux, heating with map gas and keeping the joint clean inside.
- Filter driers and drier cores: when to fit and how to choose What a filter drier and a replaceable drier core do, when to replace them and how to choose the right size and connection.
- High and low pressure switches: settings and protection explained What HP and LP switches protect against, how manual and automatic reset differ and how to set and test them.
- Superheat and subcooling: measuring with the right thermometer How superheat and subcooling are calculated, which tools you need and how to avoid the common measurement mistakes.
How the guides are written
Each guide starts from a decision that a technician or buyer actually has to make: which capacitor replaces a failed one, how many poles a contactor needs, whether a drier should be changed along with a compressor. The guide explains how the part works, which values to match, what usually goes wrong and how to check the result, and it links to the product family and models it applies to. They are written for people who work on equipment, so they assume the nameplate is in front of you.
Reading a nameplate before you order
Almost every replacement starts with the label on the old part. Four checks catch most mistakes.
- Rated values. Match capacitance in µF and voltage on a capacitor, poles, current and coil voltage on a contactor, and pressure range and reset type on a pressure switch.
- Supply. Confirm the voltage and frequency of the site. A contactor with a 24 V coil and one with a 230 V coil are different parts, and so are transformers with different primary voltages.
- Refrigerant. For parts under pressure, check that the pressure range and the listed refrigerants suit the system, since R410A and R32 run at higher pressures than R22 or R134a.
- Fit. Check terminals, connection size and mounting, and keep the model code of whatever you fit for later service.
Guides and product pages work together
Product and category pages link to the guide that covers them, where one exists, and every guide links back to the families it mentions, so you can move from a question such as which capacitor to use to a specification table in one step. If a guide you need is missing, tell us through the contact page: new guides are added as the range and the questions grow.