Klima contactors for Jamaica
Jamaica is a smaller national market in North America, and its capital is Kingston. Across Jamaica the climate is hot and humid tropical, and conditions are similar from place to place. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of contactors in Jamaica are offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Jamaica are welcome.
- Capital
- Kingston
- Population
- 2.9 million
- Area
- 10,991 km²
- Time zone
- UTC-5 all year
- Climate
- Hot and humid tropical
- Supply
- 110 V, 50 Hz
- Main ports
- Kingston
- Standards
- BSJ (Bureau of Standards Jamaica) requirements
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Jamaica · Klima Contactors overview
What Jamaica demands of contactors
In Jamaica, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed contactors and keep control boxes closed with their gaskets intact.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Jamaica supplies 110 V at 50 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of contactors against the nameplate.
Where contactors are needed in Jamaica
The widest gap between listed cities runs from New Kingston to Savanna-la-Mar, about 145 km, which keeps most road deliveries inside a day. The capital, Kingston, is also the largest listed city (about 938,000 people), which keeps most large buyers in one place. The table lists the largest cities in Jamaica with the climate stress that wears contactors fastest in each.
| City | People | Climate | What wears contactors first |
|---|---|---|---|
| Kingston | 938,000 | hot and humid tropical | moisture on terminals and corrosion |
| New Kingston | 584,000 | hot and humid tropical | terminals loosening and parts running hot |
| Spanish Town | 145,000 | hot and humid tropical | terminals loosening and parts running hot |
| Montego Bay | 83,000 | hot and humid tropical | terminals loosening and parts running hot |
| May Pen | 45,000 | hot and humid tropical | moisture on terminals and corrosion |
| Ocho Rios | 27,000 | hot and humid tropical | moisture on terminals and corrosion |
Every one of the 10 listed cities has a hot and humid tropical climate, which keeps the choice of parts consistent from city to city.
Time zone, sun and daylight in Jamaica
The clock in Kingston follows UTC-5 all year.
Sunlight at 18.0° N (Kingston): about 13 h 12 min of daylight in June, about 11 h 03 min in December, and a noon sun that reaches 85° in June and 49° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.
Size and settlement in Jamaica
Jamaica covers about 10,991 km², the 75th smallest of the 241 countries in this directory, almost exactly the size of Kosovo (10,908 km²). About 2.9 million people live there, an average of 267 people per km², which makes it densely settled, denser than 78% of the other countries in this directory. Customers are rarely far from a city, so a delivery plan by city is normally enough. Its population is similar to that of Albania (2.9 million).
Jobs in Jamaica that call for contactors
In Jamaica, these are the jobs that most often call for contactors:
- Compressor control in split and packaged air conditioners
- Heat pump defrost and reversing controls
- Hotel fan coil and VRF outdoor unit panels
- Walk-in cold rooms and refrigerated display cases
- Chiller and air handling unit starter panels
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Jamaica
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
- Confirm the supply first: Jamaica uses 110 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Jamaica that usually means BSJ (Bureau of Standards Jamaica) requirements.
Care and maintenance in Jamaica
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
With little seasonal change in temperature, air conditioning in Jamaica works almost every day. Spread checks of contactors through the year instead of waiting for a peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Burnt or welded contacts that keep the unit running when switched off
Approvals for contactors sold into Jamaica
Two sets of rules apply to contactors sold into Jamaica: the product standard, IEC 60947-4-1 (contactors and motor-starters), and the local one, BSJ (Bureau of Standards Jamaica) requirements. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Supply and delivery to Jamaica
Sea freight into Jamaica normally clears through ports such as Kingston, with onward delivery by road; urgent parts can travel by air.
The local currency is the Dollar (JMD), so confirm the quotation currency and delivery terms before you order. The main languages are English; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Contactors in Jamaica: common questions
What does the number of poles mean?
A pole is one switched circuit. A 2-pole contactor breaks both line wires of a single-phase supply, while a 3-pole contactor breaks all three phases of a three-phase supply.
What voltage should contactors be rated for in Jamaica?
The supply in Jamaica is 110 V, 50 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a contactor.
Which standards apply to contactors in Jamaica?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Jamaica the local framework is BSJ (Bureau of Standards Jamaica) requirements; request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Jamaica?
Cargo for Jamaica usually arrives through Kingston; tell us your preferred port or delivery address with your enquiry.
Which cities in Jamaica can I order contactors for?
Every listed city is covered. The largest are Kingston (938,000), New Kingston (584,000), Spanish Town (145,000), Montego Bay (83,000) and Mandeville (47,000). The country page lists the rest.
What local time and daylight should I plan for in Jamaica?
Kingston keeps UTC-5 all year. At 18.0° N there are about 13 h 12 min of daylight in June and about 11 h 03 min in December.
More Klima products for Jamaica
- Klima Capacitors in Jamaica
- Klima Delay on Make Timer in Jamaica
- Klima Transformer for HVAC in Jamaica
- Klima Pressure Switches (High & Low) in Jamaica
- Klima Flux Powder (100 g & 250 g) in Jamaica
- Klima Thermostats in Jamaica