Klima Industries

Klima 2-Pole Contactor 25 A, 24 V Coil

2-pole contactor rated 25 A with a 24 V AC coil for compressor and fan switching.

Klima Contactors ยท Model KCT-2P25-24

About this contactor

A two-pole contactor switches both supply conductors of a single-phase load, so the compressor or heater is fully disconnected when the coil drops out. This model is rated 25 A and uses a 24 V AC coil, which is the standard control voltage where a control transformer and a low-voltage thermostat run the unit. It mounts on a screw plate or on DIN rail.

The 24 V coil must be fed from a 24 V source, normally the control transformer of the unit; connecting it to 230 V destroys the coil immediately. Its current rating is a limit, not a target: choose a contactor whose rating comfortably exceeds the running current of the load, and check that its making capacity covers the locked-rotor current of a compressor. The datasheet shows whether 25 A is quoted for resistive or motor duty.

Specifications

SpecificationValue
ModelKCT-2P25-24
Poles2
Rated current25 A
Coil voltage24 V AC
Frequency50/60 Hz
MountingScrew or DIN rail

Where it fits

  • Single-phase compressors and condenser fans in packaged and split units with 24 V control
  • Electric heater stages and defrost heaters in single-phase equipment
  • Replacement of a failed 24 V two-pole contactor in a heat pump or rooftop unit
  • Control panels for small single-phase cold rooms with a 24 V control circuit

Fitting and checking

Isolate and lock off the supply. Tag every conductor, fit the new contactor on the same mounting and tighten the power terminals to the torque on the datasheet; loose connections burn the terminal block. With the control voltage restored, the contactor should pull in firmly. A buzzing or chattering contactor usually points to a low coil voltage caused by an undersized transformer or long, thin thermostat wiring.

Compared with the other contactors

This model is one of 7 in Klima Contactors; what changes from one to the next is poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.

SpecificationThis modelAcross the range
Poles22 to 3
Rated current25 A25 to 63 A
Coil voltage24 V AC24 V AC / 230 V AC

This is the smallest model in the range by rated current. The next step up is Klima 3-Pole Contactor 32 A, 24 V Coil (32 A). Quote the model code KCT-2P25-24 when you enquire so that the right size is supplied.

Questions

Can I use this contactor on a three-phase compressor?

No. A two-pole device cannot disconnect all three phases. Choose a three-pole model such as the 3-pole 25 A contactor with a 24 V coil.

How big a transformer does the coil need?

The control transformer must supply the coil's inrush as well as the other control loads. Add up the VA of every coil and relay and allow for the higher pull-in value; the Klima 24 V transformers list their VA rating.

Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-2P25-24. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.