Klima 3-Pole Contactor 32 A, 24 V Coil
3-pole contactor rated 32 A with a 24 V AC coil for compressor and fan switching.
Klima Contactors ยท Model KCT-3P32-24
About this contactor
The 32 A three-pole contactor with a 24 V AC coil is the step between the 25 A and 40 A sizes. It is used where the running current of a compressor leaves too little margin on a 25 A device, or where several motors on the same three-phase circuit are switched together. Control is at 24 V, so the contactor suits units that use a control transformer and a low-voltage thermostat or controller.
A higher current rating also brings a larger coil, so the transformer must supply more pull-in VA than for the smaller models. Check the transformer's rating against the combined coils and other control loads, otherwise the coil pulls in weakly and the contactor chatters. The mounting is the same screw plate or DIN-rail fixing as the rest of the range.
Specifications
| Specification | Value |
|---|---|
| Model | KCT-3P32-24 |
| Poles | 3 |
| Rated current | 32 A |
| Coil voltage | 24 V AC |
| Frequency | 50/60 Hz |
| Mounting | Screw or DIN rail |
Where it fits
- Three-phase compressors of medium size where 25 A is too close to the limit
- Groups of condenser fans switched by one contactor
- Packaged rooftop units that use 24 V control throughout
- Panels where one contactor feeds a compressor plus its crankcase or fan load
Fitting and checking
Use the nameplate to confirm the running and locked-rotor current of the load, then compare them with the contactor datasheet. Tighten each terminal to the torque specified and check again after a few weeks of operation, since new connections can settle. Look for discoloured insulation near the terminals at every service: it points to a loose connection long before the contactor fails.
Compared with the other contactors
This model is one of 7 in Klima Contactors; what changes from one to the next is poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Poles | 3 | 2 to 3 |
| Rated current | 32 A | 25 to 63 A |
| Coil voltage | 24 V AC | 24 V AC / 230 V AC |
Ordered by rated current, this model is number 4 of 7: the next step down is Klima 3-Pole Contactor 25 A, 24 V Coil (25 A) and the next step up is Klima 3-Pole Contactor 40 A, 230 V Coil (40 A). Quote the model code KCT-3P32-24 when you enquire so that the right size is supplied.
Questions
When should I choose 32 A rather than 25 A?
When the load's rated current leaves too little margin on a 25 A device or when the contactor is to switch more than one motor. A higher rating also gives longer contact life on a hard-working compressor.
Does a higher current rating change the coil voltage?
No. This model still uses a 24 V AC coil, but its coil draws more power, so check the transformer's VA before you fit it.
Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-3P32-24. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.