Klima Industries

Klima 3-Pole Contactor 25 A, 24 V Coil

3-pole contactor rated 25 A with a 24 V AC coil for compressor and fan switching.

Klima Contactors ยท Model KCT-3P25-24

About this contactor

Three poles mean this contactor can disconnect all three phases of a three-phase motor, which is why it is the normal choice for three-phase compressors and fan motors in small packaged and split systems. It is rated 25 A with a 24 V AC coil and mounts on a screw plate or DIN rail. The 24 V coil lets the control transformer and a low-voltage thermostat operate it safely.

A contactor does not protect a motor from overload, so it is normally fitted with an overload relay or a motor protector, and scroll compressors also need a phase-failure and phase-sequence relay because they are damaged by running backwards. For sizing, compare the compressor's rated load current and locked-rotor current with the contactor rating and utilisation category in the datasheet, rather than with the compressor's horsepower.

Specifications

SpecificationValue
ModelKCT-3P25-24
Poles3
Rated current25 A
Coil voltage24 V AC
Frequency50/60 Hz
MountingScrew or DIN rail

Where it fits

  • Three-phase compressors in small packaged and condensing units
  • Condenser fan motors and pump motors on three-phase supplies
  • Replacement for a worn 24 V three-pole contactor in rooftop units
  • Panels that use a 24 V transformer to control several contactors

Fitting and checking

Mark the three load wires before removal and fit them to the same terminals; swapping two phases reverses the rotation of a scroll compressor, which can destroy it in minutes. After fitting, check the three phase voltages and the running current of each phase; a large imbalance indicates a loose terminal, a worn contact or a supply problem rather than a faulty contactor.

Compared with the other contactors

The 7 models in Klima Contactors differ mainly in poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.

SpecificationThis modelAcross the range
Poles32 to 3
Rated current25 A25 to 63 A
Coil voltage24 V AC24 V AC / 230 V AC

This is the smallest model in the range by rated current. The next step up is Klima 3-Pole Contactor 32 A, 24 V Coil (32 A). Quote the model code KCT-3P25-24 when you enquire so that the right size is supplied.

Questions

Is a 25 A contactor enough for my compressor?

Compare it with the compressor's rated load current and locked-rotor current on the nameplate, and confirm the utilisation category in the datasheet. If the current is close to the limit, go to the 32 A or 40 A model.

Do I still need an overload relay?

Yes. The contactor only switches the current. A separate overload device, or a motor protector built into the compressor, protects the motor.

Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-3P25-24. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.