Klima 2-Pole Contactor 25 A, 230 V Coil
2-pole contactor rated 25 A with a 230 V AC coil for compressor and fan switching.
Klima Contactors ยท Model KCT-2P25-230
About this contactor
This two-pole 25 A contactor has a 230 V AC coil, so it is controlled directly from the mains without a step-down transformer. It switches both conductors of a single-phase load and mounts on a screw plate or DIN rail. The line-voltage coil is the usual choice where a cold-room controller, pressure switch or timer operates on mains voltage and drives the contactor straight from its output.
Because the control circuit is at mains voltage, thermostat and control wiring must be insulated and segregated to the same standard as the power wiring. The coil is energised for as long as the compressor runs, so a clean supply matters: low voltage gives a weak, noisy pull-in, while a coil running hot shows a supply above the coil rating or a contactor that is not closing fully.
Specifications
| Specification | Value |
|---|---|
| Model | KCT-2P25-230 |
| Poles | 2 |
| Rated current | 25 A |
| Coil voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Mounting | Screw or DIN rail |
Where it fits
- Single-phase compressors in small cold rooms and refrigerated cabinets
- Condenser fans and defrost heaters controlled by a mains-voltage controller
- Pump and fan starters in simple HVAC control panels
- Replacement of a 230 V two-pole contactor on single-phase packaged equipment
Fitting and checking
Match the coil voltage and frequency with the control circuit: this coil is for 230 V AC, so do not use it on a 24 V, 110 V or 400 V coil circuit. Check the contacts on any contactor you remove: pitted or blackened contacts show that the old part was undersized or that something is making it chatter. Mark the new contactor with the date of fitting.
Compared with the other contactors
Across the 7 models in Klima Contactors, the values that vary are poles, rated current and coil voltage. Every model in the family has the same frequency (50/60 Hz) and mounting (Screw or DIN rail), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Poles | 2 | 2 to 3 |
| Rated current | 25 A | 25 to 63 A |
| Coil voltage | 230 V AC | 24 V AC / 230 V AC |
This is the smallest model in the range by rated current. The next step up is Klima 3-Pole Contactor 32 A, 230 V Coil (32 A). Quote the model code KCT-2P25-230 when you enquire so that the right size is supplied.
Questions
When should I choose a 230 V coil instead of a 24 V one?
Choose the coil voltage that the control circuit supplies. If the controller or thermostat switches 230 V, use a 230 V coil; if the unit has a 24 V transformer, use a 24 V coil. The power contacts are the same either way.
Can I use this contactor with the 230 V delay on make timer?
Yes. The timer output can switch the coil directly and holds the compressor off for a few minutes after power returns.
Selection, care and fault-finding notes for the whole family are on the Klima Contactors page, and the contact page takes enquiries with the model code KCT-2P25-230. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.