Klima Industries

Contactors supply in Paraguay

With about 7 million people, Paraguay is a mid-sized market in South America. Its capital is Asuncion. The prevailing climate is humid subtropical, though conditions differ between regions. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.

Contactors are bought here mainly for offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Paraguay are welcome.

Capital
Asuncion
Population
7 million
Area
406,750 km²
Time zone
UTC-3 all year
Climate
Humid subtropical
Supply
230 V, 50 Hz
Standards
INTN (national institute for technology, standardization and metrology) standards

Klima Contactors models

All Klima products for Paraguay · Klima Contactors overview

Contactors and the climate in Paraguay

In Paraguay, cooling demand peaks through a long, humid summer. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed contactors and keep control boxes closed with their gaskets intact.

Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

With a 230 V, 50 Hz supply, Paraguay follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

Mapping demand for contactors in Paraguay

The capital, Asuncion, is also the largest listed city (about 1.5 million people), which keeps most large buyers in one place. About 73% of the people in listed cities live in Asuncion, Ciudad del Este and San Lorenzo; buyers are concentrated in a few centres. Climate decides how contactors age, and it changes from city to city in Paraguay: the last column shows what to expect.

CityPeopleClimateWhat wears contactors first
Asuncion1.5 millionhumid subtropicalterminals loosening and parts running hot
Ciudad del Este302,000humid subtropicalterminals loosening and parts running hot
San Lorenzo228,000humid subtropicalmoisture on terminals and corrosion
Capiata199,000humid subtropicalmoisture on terminals and corrosion
Pedro Juan Caballero75,000hot and humid tropicalterminals loosening and parts running hot
Encarnacion75,000humid subtropicalmoisture on terminals and corrosion

Climate changes from city to city: of the 17 listed cities, 12 humid subtropical and 5 hot and humid tropical, so spares chosen for one city may not suit another.

Voltage next door: Paraguay and its neighbours

Of the 3 neighbours of Paraguay listed here, 2 use the same 230 V at 50 Hz (Bolivia and Argentina), while Brazil (127/220 V, 60 Hz) differs; a part bought for one side must be checked against the other.

The sun and the clock in Paraguay

The clock in Asuncion follows UTC-3 all year.

At 25.3° S, Asuncion has about 10 h 34 min of daylight at the June solstice and about 13 h 43 min at the December solstice. The noon sun stands 41° above the horizon in June and 88° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Typical uses of contactors in Paraguay

Typical work in Paraguay that needs contactors:

  • Heat pump defrost and reversing controls
  • Walk-in cold rooms and refrigerated display cases
  • Compressor control in split and packaged air conditioners
  • Heater banks and electric reheat
  • Hotel fan coil and VRF outdoor unit panels

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick contactors for work in Paraguay

  • Check whether the control logic needs auxiliary NO or NC contacts for feedback.
  • Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
  • Confirm the supply first: Paraguay uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • For humid subtropical conditions in Paraguay, favour sealed, corrosion-resistant construction.

Keeping contactors reliable in Paraguay

  • Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.

Because Paraguay is in the southern hemisphere, the heaviest cooling load normally falls from December to March. Service contactors in October or November, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Signs of trouble

  • Burnt or welded contacts that keep the unit running when switched off

Approvals for contactors sold into Paraguay

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters); in Paraguay expect INTN (national institute for technology, standardization and metrology) standards as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering contactors for Paraguay

As a landlocked market, Paraguay receives sea freight through a transit port in a neighbouring country (Bolivia, Brazil and Argentina); air freight is the faster option for urgent parts.

The local currency is the Guarani (PYG), so confirm the quotation currency and delivery terms before you order. The main languages are Spanish and Guarani; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about contactors in Paraguay

What coil voltage should I choose?

Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.

What voltage should contactors be rated for in Paraguay?

Paraguay supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to contactors in Paraguay?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Paraguay the local framework is INTN (national institute for technology, standardization and metrology) standards; request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Paraguay?

Paraguay has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Bolivia, Brazil and Argentina and continues inland by road or rail; allow extra time for transit and border handling.

Which cities in Paraguay can I order contactors for?

Every listed city is covered. The largest are Asuncion (1.5 million), Ciudad del Este (302,000), San Lorenzo (228,000), Capiata (199,000) and Pedro Juan Caballero (75,000). The country page lists the rest.

Do the neighbours of Paraguay use the same mains supply?

Partly. Bolivia and Argentina run on 230 V at 50 Hz, but Brazil (127/220 V, 60 Hz) differs, so check the supply before ordering for the other side.

What local time and daylight should I plan for in Paraguay?

Asuncion keeps UTC-3 all year. At 25.3° S there are about 10 h 34 min of daylight in June and about 13 h 43 min in December.

More Klima products for Paraguay

Contactors in cities across Paraguay