Capacitors supply in Paraguay
Home to about 7 million people, Paraguay sits in South America. Its capital is Asuncion. The prevailing climate is humid subtropical, though conditions differ between regions. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
Capacitors are bought here mainly for offices, shops and malls, homes and apartments as well as cold stores and food distribution. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Paraguay are welcome.
- Capital
- Asuncion
- Population
- 7 million
- Area
- 406,750 km²
- Time zone
- UTC-3 all year
- Climate
- Humid subtropical
- Supply
- 230 V, 50 Hz
- Standards
- INTN (national institute for technology, standardization and metrology) standards
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Paraguay · Klima Capacitors overview
Conditions in Paraguay that affect capacitors
In Paraguay, cooling demand peaks through a long, humid summer. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
The mains supply in Paraguay is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Cities that buy capacitors in Paraguay
Asuncion is both the capital and the largest listed city, with about 1.5 million people, so the capital is also the biggest single market. From Encarnacion to Filadelfia, the longest straight-line gap between listed cities is about 696 km; so allow extra road time for the far end of the country. The table lists the largest cities in Paraguay with the climate stress that wears capacitors fastest in each.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Asuncion | 1.5 million | humid subtropical | terminals loosening and parts running hot |
| Ciudad del Este | 302,000 | humid subtropical | moisture on terminals and corrosion |
| San Lorenzo | 228,000 | humid subtropical | moisture on terminals and corrosion |
| Caaguazu | 55,000 | humid subtropical | moisture on terminals and corrosion |
| Coronel Oviedo | 51,000 | humid subtropical | moisture on terminals and corrosion |
| Concepcion | 48,000 | hot and humid tropical | terminals loosening and parts running hot |
Daylight, sun angle and time in Paraguay
Local time in Asuncion is UTC-3 all year.
Sunlight at 25.3° S (Asuncion): about 10 h 34 min of daylight in June, about 13 h 43 min in December, and a noon sun that reaches 41° in June and 88° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.
Mains supply across the borders of Paraguay
Of the 3 neighbours of Paraguay listed here, 2 use the same 230 V at 50 Hz (Bolivia and Argentina), while Brazil (127/220 V, 60 Hz) differs; a part bought for one side must be checked against the other.
Typical uses of capacitors in Paraguay
Typical work in Paraguay that needs capacitors:
- Heat pump outdoor units
- Split and window air conditioners
- Fan coil unit and blower motors
- Condensing units for walk-in cold rooms
- Commercial display fridges and freezers
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Paraguay
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Paraguay uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For humid subtropical conditions in Paraguay, favour sealed, corrosion-resistant construction.
Keeping capacitors reliable in Paraguay
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Paraguay is in the southern hemisphere, the heaviest cooling load normally falls from December to March. Service capacitors in October or November, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Approvals for capacitors sold into Paraguay
Klima capacitors follow IEC 60252-1 (AC motor capacitors); in Paraguay expect INTN (national institute for technology, standardization and metrology) standards as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.
Getting capacitors to Paraguay
As a landlocked market, Paraguay receives sea freight through a transit port in a neighbouring country (Bolivia, Brazil and Argentina); air freight is the faster option for urgent parts.
The local currency is the Guarani (PYG), so confirm the quotation currency and delivery terms before you order. The main languages are Spanish and Guarani; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Paraguay: common questions
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in Paraguay?
With a 230 V, 50 Hz supply, Paraguay follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Which standards apply to capacitors in Paraguay?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Paraguay the local framework is INTN (national institute for technology, standardization and metrology) standards; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Paraguay?
Paraguay has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Bolivia, Brazil and Argentina and continues inland by road or rail; allow extra time for transit and border handling.
Which cities in Paraguay can I order capacitors for?
Every listed city is covered. The largest are Asuncion (1.5 million), Ciudad del Este (302,000), San Lorenzo (228,000), Capiata (199,000) and Pedro Juan Caballero (75,000). The country page lists the rest.
Do the neighbours of Paraguay use the same mains supply?
Partly. Bolivia and Argentina run on 230 V at 50 Hz, but Brazil (127/220 V, 60 Hz) differs, so check the supply before ordering for the other side.
What local time and daylight should I plan for in Paraguay?
Asuncion keeps UTC-3 all year. At 25.3° S there are about 10 h 34 min of daylight in June and about 13 h 43 min in December.
More Klima products for Paraguay
- Klima Contactors in Paraguay
- Klima Terminal Crimps in Paraguay
- Klima Transformer for HVAC in Paraguay
- Klima PVC Tapes in Paraguay
- Klima Cables (3 & 4 Core) in Paraguay
- Klima Delay on Make Timer in Paraguay