Klima Capacitors

A run capacitor shifts the phase of current in the auxiliary winding of a single-phase induction motor, giving a compressor or fan motor the torque it needs to start and the efficiency it needs to keep turning. Without it, motors hum, draw excess current and overheat. In most air conditioners one dual-run capacitor serves both the compressor and the condenser fan motor, which is why a single weak part can silence the whole outdoor unit.

Klima Capacitors are supplied as single and dual (two-section) units in round and oval cases, with fast-on or screw terminals. Each model is listed with its capacitance, tolerance, rated voltage and case size, so a technician or purchasing team can match a failed part from its nameplate, or find a safe equivalent, without guesswork.

Klima Capacitors cover the motor-run and dual-run capacitors used in split, window, packaged and ducted air conditioners, heat pumps and refrigeration condensing units. Choose by capacitance, rated voltage and case style; every model is listed with those values.

Models

Related products

Supply notes by country

How capacitors are chosen and used in each country, with notes for its cities.

Key features

  • Single and dual run types. One capacitor for the compressor and fan together, or separate values where the design needs them.
  • Continuous-duty ratings. Run capacitors stay energised whenever the motor runs, so ratings are chosen for long operating hours rather than short starting pulses.
  • Wide capacitance range. Values from small fan-motor capacitors up to high-capacity compressor units, listed by µF and tolerance.
  • Voltage classes for local mains. 370 V, 440 V and higher classes for 50 Hz and 60 Hz supplies.
  • Mounting options. Round and oval cases with brackets or studs, and fast-on, wire-lead or screw terminals.
  • Straightforward replacement. The model list makes it easy to find a like-for-like replacement for common OEM values.

Where capacitors are used

  • Split and window air conditioners
  • Packaged rooftop units and ducted systems
  • Condensing units for walk-in cold rooms
  • Heat pump outdoor units
  • Fan coil unit and blower motors
  • Chiller and air-cooled condenser fans
  • Commercial display fridges and freezers
  • Ventilation and exhaust fan motors
  • Water pumps and booster sets used with HVAC plant

How to choose capacitors

  • Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
  • Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
  • Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
  • Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
  • Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.

Care and maintenance

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
  • Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
  • Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.

Common faults

  • A swollen, bulging or leaking case
  • A humming compressor that fails to start, or a fan that has to be spun by hand
  • Repeated overload trips, high running current or a unit that cuts out on hot afternoons

Questions about capacitors

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

Can I replace a capacitor with a higher µF value?

Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.

Can I fit a 440 V capacitor in place of a 370 V one?

Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

How long does a capacitor last?

Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.

Are run capacitors polarised?

No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.