Klima Industries

Klima Start Capacitor 340-408 µF 110/125 V, Round Phenolic Case

Start capacitor, 340-408 µF, rated 110/125 V, round phenolic case. The sizes either side in this style are 270-324 and 378-440 µF.

Klima Capacitors · Model KC-ST110-340-408

About this capacitor

A start capacitor in the 340-408 µF range, rated 110/125 V, in a round phenolic case. It gives a capacitor-start motor the phase shift and starting current it needs to break away under load, and it is switched out once the motor is up to speed.

The 340-408 µF window runs from 340 to 408 µF, about 20 % wide, and at its midpoint of 374 µF the capacitor presents roughly 8.51 ? at 50 Hz. A higher µF range passes more starting current through the auxiliary winding, which is why bigger motors, with more load to break away, are fitted with higher ranges.

Specifications

SpecificationValue
ModelKC-ST110-340-408
Capacitance340-408 µF
Rated voltage110 / 125 VAC
TypeStart
CaseRound phenolic

Where it fits

  • Plant where start capacitors are stocked as spares because a failure stops production
  • Equipment that has to start under load, such as crushers and large fans, on single-phase supply
  • Units with a long start-up time that stress the start relay as well as the capacitor
  • Equipment built for 110-120 V supplies, including imported machinery

Fitting and checking

Use the nearest range only if the motor maker allows it. A lower µF range reduces starting torque and a higher one raises starting current, which strains the start winding and the relay. If the exact 340-408 µF range is not to hand, ask for the nearest permitted range rather than guessing.

Compared with the other capacitors

This model is one of 116 in Klima Capacitors; what changes from one to the next is capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance340-408 µF0.5 to 480 µF
Rated voltage110 / 125 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run
CaseRound phenolicRound, Oval, Oval aluminium, Round phenolic

In the KC-ST110 series, the next step down by capacitance is Klima Start Capacitor 270-324 µF 110/125 V, Round Phenolic Case (270-324 µF) and the next step up is Klima Start Capacitor 378-440 µF 110/125 V, Round Phenolic Case (378-440 µF). Quote the model code KC-ST110-340-408 when you enquire so that the right size is supplied.

Questions

Which ranges sit either side of 340-408 µF?

Among the 110/125 V start capacitors the next range down is 270-324 µF and the next range up is 378-440 µF. Quote the range and the voltage class when you enquire.

How long can a start capacitor stay in circuit?

Only for a second or two at each start. The motor's relay, centrifugal switch or electronic switch should take it out of circuit as the motor reaches speed. If a 340-408 µF capacitor is warm to the touch after a normal start, check the switching device before the capacitor.

How do I tell whether the start capacitor has failed?

A motor that hums but does not turn, takes a long time to reach speed or trips its overload on start often has a failed start capacitor. Isolate and discharge the part and read it with a capacitance meter: a reading below 340 µF on a 340-408 µF part means it has lost capacity. A bulged, split or leaking case is an immediate fail.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-ST110-340-408. For background reading, see the guide How to choose a run capacitor for an air conditioner.