Start capacitor, 378-440 µF, rated 110/125 V, round phenolic case. It is the 5th of 6 ranges in this class, from 161 to 480 µF.

Klima Capacitors · Model KC-ST110-378-440

About this capacitor

Where a compressor, pump or machine needs a hard push to start, this Klima 378-440 µF start capacitor, in a round phenolic case, provides it. The 110/125 V rating is the voltage class to match against the original, and the µF range is the window the capacitance is specified to fall within.

The 378-440 µF figure is a range, not a single value: a start capacitor is specified by the window its capacitance may fall in. This window is 16 % wide and centres on about 409 µF, where the reactance is near 7.78 ? at 50 Hz and 6.49 ? at 60 Hz.

Specifications

SpecificationValue
ModelKC-ST110-378-440
Capacitance378-440 µF
Rated voltage110 / 125 VAC
TypeStart
CaseRound phenolic

Where it fits

  • Plant where start capacitors are stocked as spares because a failure stops production
  • Motors that hum and heat up without turning because the start capacitor has failed
  • Replacing a phenolic-case start capacitor marked 110/125 V on a 110-120 V motor
  • Big compressors and pump sets that rely on a high-capacity capacitor start

Fitting and checking

After fitting, test the start sequence: the motor should accelerate promptly, the relay or switch should drop out, and the capacitor should stay cool to the touch once the motor is running. A part from the 378-440 µF range that is warm after a normal start points to a relay or switch fault.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance378-440 µF0.5 to 480 µF
Rated voltage110 / 125 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run
CaseRound phenolicRound, Oval, Oval aluminium, Round phenolic

In the KC-ST110 series, the next step down by capacitance is Klima Start Capacitor 340-408 µF 110/125 V, Round Phenolic Case (340-408 µF) and the next step up is Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case (400-480 µF). Quote the model code KC-ST110-378-440 when you enquire so that the right size is supplied.

Questions

What is the next range up or down from 378-440 µF?

Among the 110/125 V start capacitors the next range down is 340-408 µF and the next range up is 400-480 µF. Quote the range and the voltage class when you enquire.

Can a start capacitor be used as a run capacitor?

No. Start capacitors are built for brief, intermittent duty and overheat when left in circuit. A motor that needs a capacitor all the time needs a run capacitor of the µF value on its nameplate, from the run capacitors in this family.

Is it safe to handle a start capacitor after the machine is switched off?

Not until it is discharged. A part in the middle of the 378-440 µF range holds about 5.91 J when charged to the 170 V peak of a 120 V supply. Isolate the supply, then discharge the terminals through a suitable resistor before touching the part.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-ST110-378-440. For background reading, see the guide How to choose a run capacitor for an air conditioner.