Buying capacitors in Liechtenstein
Liechtenstein is a compact market in Europe, and its capital is Vaduz. The climate across Liechtenstein is continental, with only modest differences from one place to another. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Demand for capacitors comes mostly from offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Liechtenstein are welcome.
- Capital
- Vaduz
- Population
- 38,000
- Area
- 160 km²
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- Climate
- Continental
- Supply
- 230 V, 50 Hz
- Standards
- CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Liechtenstein · Klima Capacitors overview
What Liechtenstein demands of capacitors
In Liechtenstein, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
The mains supply in Liechtenstein is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Capacitors across the cities of Liechtenstein
Vaduz, the capital, is the only city listed for Liechtenstein, with about 5,197 people, so every enquiry from the country can be tied to one place. Parts for Liechtenstein are best planned around Vaduz, which has a continental climate. For capacitors in Vaduz, watch for brittle insulation and hard starting before anything else.
The sun and the clock in Liechtenstein
Vaduz keeps UTC+1, moving to UTC+2 while daylight saving applies.
At 47.1° N, Vaduz has about 15 h 55 min of daylight at the June solstice and about 8 h 29 min at the December solstice. The noon sun stands 66° above the horizon in June and 19° in December, and the summer sun is high, so outdoor units in unshaded spots take strong direct heat.
Mains supply across the borders of Liechtenstein
Liechtenstein borders Switzerland and Austria. Both use a nominal 230 V at 50 Hz, the same as Liechtenstein, so an electrical rating that fits one side of the border fits the other.
Where capacitors are used in Liechtenstein
Typical work in Liechtenstein that needs capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
- Ventilation and exhaust fan motors
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Liechtenstein
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Confirm the supply first: Liechtenstein uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For continental conditions in Liechtenstein, allow for wide seasonal temperature swings.
Care and maintenance in Liechtenstein
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
Liechtenstein lies in the northern hemisphere, where cooling demand usually peaks from June to August. Schedule inspections of capacitors for April or May, ahead of that peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Which standards apply to capacitors in Liechtenstein
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Liechtenstein, the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations, so match the datasheet to both and ask for any conformity documents your project needs.
Ordering capacitors for Liechtenstein
Liechtenstein has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Switzerland and Austria and continues inland by road or rail; allow extra time for transit and border handling.
The local currency is the Franc (CHF), so confirm the quotation currency and delivery terms before you order. The main languages are German; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Liechtenstein
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Liechtenstein?
With a 230 V, 50 Hz supply, Liechtenstein follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Which standards apply to capacitors in Liechtenstein?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Liechtenstein the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Liechtenstein?
As a landlocked market, Liechtenstein receives sea freight through a transit port in a neighbouring country (Switzerland and Austria); air freight is the faster option for urgent parts.
Which city in Liechtenstein can I order capacitors for?
Vaduz (5,197) is the one city listed for Liechtenstein, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
Do the neighbours of Liechtenstein use the same mains supply?
Yes. Both listed neighbours (Switzerland and Austria) run on a nominal 230 V at 50 Hz, the same as Liechtenstein, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Liechtenstein?
Vaduz keeps UTC+1, moving to UTC+2 while daylight saving applies. At 47.1° N there are about 15 h 55 min of daylight in June and about 8 h 29 min in December.
More Klima products for Liechtenstein
- Klima Contactors in Liechtenstein
- Klima Terminal Crimps in Liechtenstein
- Klima Transformer for HVAC in Liechtenstein
- Klima Copper Coils & Tubes in Liechtenstein
- Klima Pressure Switches (High & Low) in Liechtenstein
- Klima Thermostats in Liechtenstein