Klima CBB61 Start/Run Capacitor 1 µF 500 V AC
CBB61 start/run capacitor with 1 µF capacity and a 500 V AC rating. It is the 3rd of 19 sizes in this style, from 0.5 to 12 µF.
Klima Capacitors · Model KC-C61-1
About this capacitor
Small single-phase motors rely on a capacitor to create the second phase that turns them, and this Klima 1 µF CBB61 part does that job at up to 500 V AC. It is listed as a start/run capacitor for fans, blowers and similar light loads. A terminal-type version of this 1 µF value is listed separately, so choose the connection style that matches the old part.
Tolerance: for a ±5 % part a healthy 1 µF capacitor reads between 0.95 and 1.05 µF, and for ±10 % between 0.9 and 1.1 µF. Fan capacitors are often supplied to ±5 %, but check the figure printed on the body. A reading outside the window means the part has lost capacity.
Specifications
| Specification | Value |
|---|---|
| Model | KC-C61-1 |
| Capacitance | 1 µF |
| Rated voltage | 500 VAC |
| Type | Start/run |
Where it fits
- Air purifier and humidifier fan motors
- Equipment that lists a CBB61 capacitor, or a film capacitor of the same value and a voltage rating of 500 V AC or less
- Spares for small-appliance repair benches
- Small extraction and ventilation fans with low-power single-phase motors
Fitting and checking
A fan that has slowed over the years often has a capacitor that has lost capacity. Replace the 1 µF part, then check that the fan reaches full speed and runs quietly. If it still turns slowly, look at the bearings and the winding before suspecting the new capacitor.
Compared with the other capacitors
Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 1 µF | 0.5 to 480 µF |
| Rated voltage | 500 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start/run | Single run, Dual run, Start, Start/run |
In the KC-C61 series, the next step down by capacitance is Klima CBB61 Start/Run Capacitor 0.8 µF 500 V AC (0.8 µF) and the next step up is Klima CBB61 Start/Run Capacitor 1.2 µF 500 V AC (1.2 µF). Quote the model code KC-C61-1 when you enquire so that the right size is supplied.
Questions
If 1 µF is not the right size, which neighbouring sizes does Klima list?
Among the CBB61 capacitors the next size down is 0.8 µF and the next size up is 1.2 µF. All are rated 500 V AC.
Can two capacitors be used to make up the value?
Capacitors in parallel add their values, so two parts can make up a larger µF figure. It is a workaround only: a single 1 µF part is neater and safer, and each capacitor must carry the full voltage rating.
Is it safe to touch a fan capacitor after switching off?
Not straight away. A 1 µF capacitor charged to the 325 V peak of a 230 V supply holds about 52.8 mJ, enough for an unpleasant shock. Isolate the supply, then discharge the terminals through a suitable resistor before handling it.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-C61-1. For background reading, see the guide How to choose a run capacitor for an air conditioner.