Motor start capacitor with 108-130 µF capacity and a 250 V rating. It is the 18th of 33 ranges in this class, from 25 to 400 µF.

Klima Capacitors · Model KC-MS-108-130

About this capacitor

Klima's 108-130 µF, 250 V start capacitor is built for short, repeated starting duty rather than for continuous running. The range figure is how start capacitors are specified: any reading inside 108 to 130 µF is a part performing as intended.

Because a start capacitor works for such a short time in each cycle it is built small for its µF value, and the price of that is a low tolerance for abuse. Many starts in quick succession, or a relay that fails to drop the capacitor out, will cook the part. If a 108-130 µF capacitor feels hot a minute after a normal start, check the relay or switch before the capacitor.

Specifications

SpecificationValue
ModelKC-MS-108-130
Capacitance108-130 µF
Rated voltage250 VAC
TypeStart

Where it fits

  • Motors on 220-240 V supplies that specify a 250 V start capacitor
  • Commercial refrigeration and cold-room condensing units with start relays
  • Single-phase borehole and booster pumps
  • Concrete mixers, saw benches and similar loaded machinery

Fitting and checking

Match the µF range and the voltage class to the old capacitor or the motor data. A start capacitor in the 108-130 µF range should measure inside that window when new; read the old part out of circuit with a capacitance meter and replace it if it is below 108 µF. Discharge it first through a suitable resistor.

Compared with the other capacitors

This model is one of 116 in Klima Capacitors; what changes from one to the next is capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance108-130 µF0.5 to 480 µF
Rated voltage250 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run

In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 100-125 µF 250 V (100-125 µF) and the next step up is Klima Motor Start Capacitor 124-149 µF 250 V (124-149 µF). Quote the model code KC-MS-108-130 when you enquire so that the right size is supplied.

Questions

If 108-130 µF is not right, which neighbouring ranges does Klima list?

Among the 250 V start capacitors the next range down is 100-125 µF and the next range up is 124-149 µF. Quote the range and the voltage class when you enquire.

How long can a start capacitor stay in circuit?

Only for a second or two at each start. The motor's relay, centrifugal switch or electronic switch should take it out of circuit as the motor reaches speed. If a 108-130 µF capacitor is warm to the touch after a normal start, check the switching device before the capacitor.

Can I test a 108-130 µF start capacitor with a multimeter?

A meter with a capacitance range gives the clearest answer: read the part out of circuit and compare it with the 108 to 130 µF window, after discharging it. A resistance test can show a shorted or open capacitor, but only a capacitance reading tells you whether the value is still inside the window.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-108-130. For background reading, see the guide How to choose a run capacitor for an air conditioner.