Klima CBB65 Dual Run Capacitor 45+5 µF
Klima model KC-C65D-45-5 is a 45+5 µF CBB65 dual run capacitor. HERM takes the 45 µF section and FAN the 5 µF section. Quote the voltage you need with your enquiry.
Klima Capacitors · Model KC-C65D-45-5
About this capacitor
For outdoor air-conditioning units that specify 45+5 µF, this CBB65 dual run capacitor replaces the old can in one operation. The 45 µF section is for the compressor and the 5 µF section for the fan, and both values must agree with the nameplate.
The 45:5 proportion, about 9 to one, reflects the different jobs: the compressor motor needs a large capacitance to develop torque under load, while the fan motor needs only a small one. A different pair of values shifts the balance for one or both motors.
Specifications
| Specification | Value |
|---|---|
| Model | KC-C65D-45-5 |
| Capacitance | 45 + 5 µF |
| Type | Dual run |
Where it fits
- Ducted split systems whose outdoor unit data plate lists a dual run capacitor
- Equipment that lists a CBB65 dual capacitor, or a sealed dual run capacitor of the same 45+5 µF pairing
- Retrofit work where two failed single capacitors are replaced by one dual part, once the wiring plan has been checked
- Heat-pump outdoor units, where one can serves the compressor and the fan in both modes
Fitting and checking
Measure each section of the old can before ordering: C to HERM should be near 45 µF and C to FAN near 5 µF. A low reading on either section means the can is finished. Fit the 45+5 µF replacement in the same bracket, tighten it so the case cannot rotate, and check that every connector is tight.
Compared with the other capacitors
The 116 models in Klima Capacitors differ mainly in capacitance and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 45 + 5 µF | 0.5 to 480 µF |
| Type | Dual run | Single run, Dual run, Start, Start/run |
In the KC-C65D series, the next step down by capacitance is Klima CBB65 Dual Run Capacitor 40+5 µF (40 + 5 µF) and the next step up is Klima CBB65 Dual Run Capacitor 50+5 µF (50 + 5 µF). Quote the model code KC-C65D-45-5 when you enquire so that the right size is supplied.
Questions
If 45+5 µF is not right, which neighbouring pairings does Klima list?
Within the CBB65 dual run capacitors the next pairing down is 40+5 µF and the next pairing up is 50+5 µF. Quote both section values with the voltage when you enquire.
What if only one section has failed?
Replace the whole can. The sections share one case and one construction, and a part with one section out of tolerance has aged as a whole. A new 45+5 µF can restores both the compressor and the fan sections at once.
How do I tell whether the 45+5 µF capacitor has failed?
A compressor that hums and trips, an outdoor fan that spins slowly or not at all, or a swollen or leaking can all point to a weak dual capacitor. Isolate and discharge the part, then read each section with a capacitance meter: below about 40.5 µF on the compressor section or 4.5 µF on the fan section means the can has lost capacity.