Klima Industries

Klima CBB65 Dual Run Capacitor 40+5 µF

CBB65 dual run capacitor, 40+5 µF. It is the 2nd of 6 dual sizes, from 35 to 60 µF. Quote the voltage you need with your enquiry.

Klima Capacitors · Model KC-C65D-40-5

About this capacitor

A CBB65 dual-section capacitor of 40+5 µF: one can, three connections for common, compressor and fan. Check the voltage printed on the old part and quote it with your enquiry so that the rating supplied matches the original or exceeds it.

Voltage ratings matter as much as capacity, because the voltage across a run capacitor in service is higher than the supply. Confirm the voltage printed on the old capacitor and choose a replacement rated at least as high. Together the two sections store about 2.38 J at the 325 V peak of a 230 V supply, so discharge both before you touch the can.

Specifications

SpecificationValue
ModelKC-C65D-40-5
Capacitance40 + 5 µF
TypeDual run

Where it fits

  • Heat-pump outdoor units, where one can serves the compressor and the fan in both modes
  • Rooftop packaged units with single-phase compressors
  • Outdoor fans that stop or run slowly while the compressor still runs, a sign that the small section is weak
  • Outdoor units where the compressor needs 40 µF and the fan motor 5 µF

Fitting and checking

Dual capacitors are normally marked C (common), HERM (compressor) and FAN. Photograph the wiring and note which wire sits on each terminal before you remove the old can, isolate and discharge it, then transfer the wires one at a time: C to C, HERM to HERM, FAN to FAN. Swapping HERM and FAN puts 40 µF on the fan and 5 µF on the compressor.

Compared with the other capacitors

Across the 116 models in Klima Capacitors, the values that vary are capacitance and type.

SpecificationThis modelAcross the range
Capacitance40 + 5 µF0.5 to 480 µF
TypeDual runSingle run, Dual run, Start, Start/run

In the KC-C65D series, the next step down by capacitance is Klima CBB65 Dual Run Capacitor 35+5 µF (35 + 5 µF) and the next step up is Klima CBB65 Dual Run Capacitor 45+5 µF (45 + 5 µF). Quote the model code KC-C65D-40-5 when you enquire so that the right size is supplied.

Questions

What is the next size up or down from 40+5 µF?

Within the CBB65 dual run capacitors the next pairing down is 35+5 µF and the next pairing up is 45+5 µF. Quote both section values with the voltage when you enquire.

Which voltage rating should I choose?

Use the rating printed on the old capacitor, or a higher one. Run capacitors for 230 V equipment are commonly marked 370 V, 440 V or 450 V, but the nameplate and the old can decide. Quote the voltage with your enquiry for the 40+5 µF model so that the right part can be confirmed.

What should I check after fitting the new 40+5 µF can?

Run the unit and watch both motors: the compressor should start without a long hum and the fan should reach full speed at once. Compare the compressor running current with the data plate figure; a current well above it means something other than the capacitor, such as the compressor itself or the supply, needs attention.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-C65D-40-5. For background reading, see the guide How to choose a run capacitor for an air conditioner.