Capacitors for the United States
The United States is one of the largest national markets in the world in North America, and its capital is Washington, D.C. The prevailing climate is temperate, though conditions differ between regions. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
The main users of capacitors in the United States are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in the United States.
- Capital
- Washington, D.C.
- Population
- 327.2 million
- Area
- 9,629,091 km²
- Time zone
- UTC-5, moving to UTC-4 while daylight saving applies
- Climate
- Temperate
- Supply
- 120/240 V, 60 Hz
- Main ports
- Los Angeles / Long Beach, New York / New Jersey, Savannah, Houston
- Standards
- UL / ETL listing where applicable, National Electrical Code (NEC) wiring rules and EPA refrigerant-handling requirements
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for the United States · Klima Capacitors overview
Conditions in the United States that affect capacitors
In the United States, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
The United States supplies 120/240 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
Where capacitors are needed in the United States
The capital is Washington, D.C., but the biggest listed city is New York, about 328 km away to the north-east of it; quote the delivery city on every enquiry. From South Boston to Honolulu, the longest straight-line gap between listed cities is about 8,179 km; so freight between the far ends takes days by road and urgent parts often go by air. The table lists the largest cities in the United States with the climate stress that wears capacitors fastest in each.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| New York | 8.8 million | temperate | expansion and contraction loosening joints |
| Los Angeles | 3.8 million | hot and arid | terminals loosening and parts running hot |
| Chicago | 2.7 million | continental | brittle insulation and hard starting |
| Houston | 2.3 million | humid subtropical | terminals loosening and parts running hot |
| San Antonio | 1.5 million | humid subtropical | terminals loosening and parts running hot |
| San Diego | 1.4 million | hot and arid | dust on contacts and blocked cooling |
The 60 listed cities fall into 6 climate types (21 humid subtropical, 12 continental, 11 temperate, 10 hot and arid, 5 Mediterranean and 1 hot and humid tropical), so parts are best chosen for the city where they will run.
Mains supply across the borders of the United States
Of the 3 neighbours of the United States listed here, 1 uses the same 120/240 V at 60 Hz (Canada), while Mexico (127/220 V, 60 Hz) and Cuba (110/220 V, 60 Hz) differ; a part bought for one side must be checked against the other.
The United States in numbers
At roughly 9,629,091 km², the United States is the 3rd largest of the 241 countries covered by this directory, almost exactly the size of China (9,596,960 km²). About 327.2 million people live there, an average of 34 people per km², which makes it moderately settled, sparser than 75% of the other countries in this directory. People and businesses cluster around the main cities, so say which city or region the delivery is for.
Where capacitors are used in the United States
In the United States, these are the jobs that most often call for capacitors:
- Fan coil unit and blower motors
- Chiller and air-cooled condenser fans
- Split and window air conditioners
- Packaged rooftop units and ducted systems
- Ventilation and exhaust fan motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for the United States
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Confirm the supply first: the United States uses 120/240 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For temperate conditions in the United States, allow for wide seasonal temperature swings.
Care and maintenance in the United States
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because the United States is in the northern hemisphere, the heaviest cooling load normally falls in July and August. Service capacitors in May or June, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Standards and paperwork for capacitors in the United States
Klima capacitors follow IEC 60252-1 (AC motor capacitors); in the United States expect UL / ETL listing where applicable, National Electrical Code (NEC) wiring rules and EPA refrigerant-handling requirements as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.
Supply and delivery to the United States
Sea freight into the United States normally clears through ports such as Los Angeles / Long Beach, New York / New Jersey, Savannah and Houston, with onward delivery by road; urgent parts can travel by air.
The local currency is the Dollar (USD), so confirm the quotation currency and delivery terms before you order. The main languages are English, Spanish, Hawaiian and French; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in the United States
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in the United States?
The supply in the United States is 120/240 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.
Which standards apply to capacitors in the United States?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In the United States the local framework is UL / ETL listing where applicable, National Electrical Code (NEC) wiring rules and EPA refrigerant-handling requirements; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to the United States?
Cargo for the United States usually arrives through Los Angeles / Long Beach, New York / New Jersey, Savannah and Houston; tell us your preferred port or delivery address with your enquiry.
Which cities in the United States can I order capacitors for?
Every listed city is covered. The largest are New York (8.8 million), Los Angeles (3.8 million), Chicago (2.7 million), Houston (2.3 million) and Phoenix (1.7 million). The country page lists the rest.
Do the neighbours of the United States use the same mains supply?
Partly. Canada runs on 120/240 V at 60 Hz, but Mexico (127/220 V, 60 Hz) and Cuba (110/220 V, 60 Hz) differ, so check the supply before ordering for the other side.
What local time and daylight should I plan for in the United States?
Washington DC keeps UTC-5, moving to UTC-4 while daylight saving applies. At 38.9° N there are about 14 h 54 min of daylight in June and about 9 h 26 min in December.
More Klima products for the United States
- Klima Contactors in the United States
- Klima Terminal Crimps in the United States
- Klima Transformer for HVAC in the United States
- Klima Map Gas (Brazing & Welding) in the United States
- Klima Pressure Switches (High & Low) in the United States
- Klima Filter Driers in the United States