Klima Motor Start Capacitor 160-200 µF 250 V
Klima model KC-MS-160-200 is a 160-200 µF motor start capacitor rated 250 V. The range midpoint is about 180 µF.
Klima Capacitors · Model KC-MS-160-200
About this capacitor
A start capacitor in the 160-200 µF range, rated 250 V. It gives a capacitor-start motor the phase shift and starting current it needs to break away under load, and it is switched out once the motor is up to speed.
Stored energy deserves respect. At the 325 V peak of a 230 V supply a capacitor in the middle of this range (180 µF) holds about 9.51 J. Start capacitors are often fitted with a bleed resistor, but do not rely on it: discharge the terminals through a suitable resistor before you handle the part.
Specifications
| Specification | Value |
|---|---|
| Model | KC-MS-160-200 |
| Capacitance | 160-200 µF |
| Rated voltage | 250 VAC |
| Type | Start |
Where it fits
- Workshop machinery such as large saws and planers on single-phase supplies
- Heavy-duty single-phase pumps and pressure sets
- Replacements for a 250 V start capacitor of the same µF range
- Replacement where the motor takes several seconds to start and the lights dip
Fitting and checking
Match the µF range and the voltage class to the old capacitor or the motor data. A start capacitor in the 160-200 µF range should measure inside that window when new; read the old part out of circuit with a capacitance meter and replace it if it is below 160 µF. Discharge it first through a suitable resistor.
Compared with the other capacitors
Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 160-200 µF | 0.5 to 480 µF |
| Rated voltage | 250 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start | Single run, Dual run, Start, Start/run |
In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 145-172 µF 250 V (145-172 µF) and the next step up is Klima Motor Start Capacitor 161-193 µF 250 V (161-193 µF). Quote the model code KC-MS-160-200 when you enquire so that the right size is supplied.
Questions
What is the next range up or down from 160-200 µF?
Among the 250 V start capacitors the next range down is 145-172 µF and the next range up is 161-193 µF. Quote the range and the voltage class when you enquire.
Can a start capacitor be used as a run capacitor?
No. Start capacitors are built for brief, intermittent duty and overheat when left in circuit. A motor that needs a capacitor all the time needs a run capacitor of the µF value on its nameplate, from the run capacitors in this family.
Can a higher range help a heavy load start?
Not as a rule. A higher range raises the starting current in the auxiliary winding, which can overheat the winding and wear the relay or switch. Stay with the 160-200 µF range the motor maker specified; if the load has changed, check the motor data or ask before choosing another range.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-160-200. For background reading, see the guide How to choose a run capacitor for an air conditioner.