Klima Industries

Klima Motor Start Capacitor 145-172 µF 250 V

Motor start capacitor for motors that need 145-172 µF at 250 V. It is the 22nd of 33 ranges in this class, from 25 to 400 µF.

Klima Capacitors · Model KC-MS-145-172

About this capacitor

The 145-172 µF, 250 V start capacitor is listed by Klima for single-phase induction motors that need extra torque to get a load moving. It is wired in series with the start winding only while the motor accelerates, then dropped out of circuit.

Voltage class: 250 V. This class is commonly specified for motors on 220-240 V supplies. Match the rating on the original, and use a higher class if the exact one is not to hand.

Specifications

SpecificationValue
ModelKC-MS-145-172
Capacitance145-172 µF
Rated voltage250 VAC
TypeStart

Where it fits

  • Commercial refrigeration compressors with a high starting torque requirement
  • Motors on 220-240 V supplies that specify a 250 V start capacitor
  • Heavy-duty single-phase pumps and pressure sets
  • Workshop machinery such as large saws and planers on single-phase supplies

Fitting and checking

Fit the 145-172 µF capacitor close to where the old part sat, keep the leads short and clear of hot surfaces such as the motor frame or a compressor shell, and tighten every terminal firmly. A start capacitor carries a large current for a moment at each start, and a loose connection heats and burns the terminal long before the capacitor itself fails.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance145-172 µF0.5 to 480 µF
Rated voltage250 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run

In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 130-156 µF 250 V (130-156 µF) and the next step up is Klima Motor Start Capacitor 160-200 µF 250 V (160-200 µF). Quote the model code KC-MS-145-172 when you enquire so that the right size is supplied.

Questions

Which ranges sit either side of 145-172 µF?

Among the 250 V start capacitors the next range down is 130-156 µF and the next range up is 160-200 µF. Quote the range and the voltage class when you enquire.

How long can a start capacitor stay in circuit?

Only for a second or two at each start. The motor's relay, centrifugal switch or electronic switch should take it out of circuit as the motor reaches speed. If a 145-172 µF capacitor is warm to the touch after a normal start, check the switching device before the capacitor.

What happens if the start capacitor reads below range?

A reading below 145 µF means the capacitor supplies less starting current than the motor was designed for, so the motor starts slowly, struggles against its load or trips the overload. Starting torque falls as capacity is lost, so replace the part before it fails completely.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-145-172. For background reading, see the guide How to choose a run capacitor for an air conditioner.