Motor start capacitor, 233-280 µF, rated 250 V. It is typically fitted to larger compressors and hard-starting loads.

Klima Capacitors · Model KC-MS-233-280

About this capacitor

A start capacitor in the 233-280 µF range, rated 250 V. It gives a capacitor-start motor the phase shift and starting current it needs to break away under load, and it is switched out once the motor is up to speed.

Because a start capacitor works for such a short time in each cycle it is built small for its µF value, and the price of that is a low tolerance for abuse. Many starts in quick succession, or a relay that fails to drop the capacitor out, will cook the part. If a 233-280 µF capacitor feels hot a minute after a normal start, check the relay or switch before the capacitor.

Specifications

SpecificationValue
ModelKC-MS-233-280
Capacitance233-280 µF
Rated voltage250 VAC
TypeStart

Where it fits

  • Workshop machinery such as large saws and planers on single-phase supplies
  • Commercial refrigeration compressors with a high starting torque requirement
  • Motors on 220-240 V supplies that specify a 250 V start capacitor
  • Replacement where the motor takes several seconds to start and the lights dip

Fitting and checking

Check that the case suits the mounting: the listing does not give a case shape, so measure the old capacitor and compare it with the size you are quoted. Isolate the supply, photograph the wiring, then move the wires across one at a time. Make sure the terminals are tight, because the high starting current heats a poor connection quickly.

Compared with the other capacitors

Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance233-280 µF0.5 to 480 µF
Rated voltage250 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run

In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 216-260 µF 250 V (216-260 µF) and the next step up is Klima Motor Start Capacitor 250-315 µF 250 V (250-315 µF). Quote the model code KC-MS-233-280 when you enquire so that the right size is supplied.

Questions

If 233-280 µF is not right, which neighbouring ranges does Klima list?

Among the 250 V start capacitors the next range down is 216-260 µF and the next range up is 250-315 µF. Quote the range and the voltage class when you enquire.

What is the difference between 250 V and 330 V start capacitors?

Both are used on 220-240 V motors; the 330 V class has more voltage margin. A 330 V part can replace a 250 V one of the same µF range, but not the reverse. This 233-280 µF model is the 250 V class.

Why does a start capacitor fail so often?

It works hard for a very short time. Heat from repeated starts, a supply that sags and prolongs starting, and a relay that holds the capacitor in circuit are the usual causes. A 233-280 µF part that has failed once should prompt a check of the relay or switch before the replacement goes in.