Klima Transformer for HVAC

Most thermostats, contactor coils, zone valves and relays in HVAC equipment operate at 24 V AC, so a control transformer sits between the mains and the control circuit. It isolates the low-voltage wiring from the mains, which makes thermostat wiring safe to handle, and it limits the available current so a fault does not destroy the controls.

Klima Transformers for HVAC are compact control transformers with a listed primary voltage (for example 110/120 V, 220/240 V or 380/400 V), a 24 V secondary and a VA rating to suit the load. Choose a VA rating above the total load of coils, valves and controllers, because an overloaded transformer overheats and can burn out.

Klima Transformers for HVAC step mains voltage down to the 24 V (or other low voltage) that thermostats, contactor coils, valves and control boards use. Choose by primary and secondary voltage, VA rating and mounting.

Models

Related products

Supply notes by country

How HVAC transformers are chosen and used in each country, with notes for its cities.

Key features

  • Voltage options. Primary voltages for common 50 Hz and 60 Hz supplies with a 24 V AC secondary.
  • VA ratings. A graded range so that you can match the total control load with headroom.
  • Isolated secondary. Separates low-voltage control wiring from the mains.
  • Thermal protection options. Fuses or thermal cut-outs on selected models.
  • Easy mounting. Foot, plate or DIN mounting with flying leads or screw terminals, listed per model.

Where HVAC transformers are used

  • 24 V control circuits in split and packaged air conditioners
  • Thermostat, contactor and relay supplies
  • Fan coil unit and zone valve power
  • Chiller and AHU control panels
  • Cold room and refrigeration controllers
  • Heat pump control boards
  • Building automation field devices
  • Pump and fan control panels
  • Lighting and signalling circuits in plant rooms

How to choose HVAC transformers

  • Match the primary voltage and frequency to the local supply; a transformer rated for 60 Hz only can overheat on a 50 Hz supply, so check that the frequency rating covers yours.
  • Add up the VA of all 24 V loads (coils, valves, controls) and choose a rating at least 20 % above the total.
  • Check the secondary voltage the thermostat and contactors need; most HVAC controls use 24 V AC.
  • Select protection to suit the panel design: fused primary or secondary, or a thermal cut-out.
  • Check the mounting style and terminal layout against your panel space.

Care and maintenance

  • Fit a fuse or breaker on the primary as the panel design requires, and a fuse on the secondary where the equipment manual calls for it.
  • Tighten terminals and keep ventilation slots clear of dust.
  • If a transformer runs hot or hums loudly, check for overload or a shorted coil before replacing it.

Common faults

  • A control circuit that is dead although mains is present
  • A hot, humming or smelling transformer
  • A blown secondary fuse that keeps repeating

Questions about HVAC transformers

Why do HVAC systems use 24 V controls?

Low voltage makes thermostat wiring safer and easier to install, allows thin cable, and lets one standard voltage serve thermostats, contactors and valves.

How do I choose the VA rating?

Add up the VA draw of every load on the 24 V circuit, including contactor coils and valves, then add about 20 % spare capacity.

Can I replace a 40 VA transformer with a larger one?

Yes. A higher VA rating is safe because the load only draws what it needs, as long as voltages and frequency match. A lower VA rating can overheat.

What happens if a transformer is overloaded?

It runs hot, the voltage sags, relays chatter, and the winding may burn out or the fuse may blow.

Can I use a 50 Hz transformer on a 60 Hz supply?

Usually yes, since a 50 Hz design runs cooler on 60 Hz, but a 60 Hz-only transformer may overheat on 50 Hz. Check the frequency marking.

Is a transformer the same as a power supply?

A transformer only steps AC voltage down. A power supply also rectifies and regulates the output to DC.

Guides for HVAC transformers