Klima Transformer for HVAC
Most thermostats, contactor coils, zone valves and relays in HVAC equipment operate at 24 V AC, so a control transformer sits between the mains and the control circuit. It isolates the low-voltage wiring from the mains, which makes thermostat wiring safe to handle, and it limits the available current so a fault does not destroy the controls.
Klima Transformers for HVAC are compact control transformers with a listed primary voltage (for example 110/120 V, 220/240 V or 380/400 V), a 24 V secondary and a VA rating to suit the load. Choose a VA rating above the total load of coils, valves and controllers, because an overloaded transformer overheats and can burn out.
Klima Transformers for HVAC step mains voltage down to the 24 V (or other low voltage) that thermostats, contactor coils, valves and control boards use. Choose by primary and secondary voltage, VA rating and mounting.
Models
- Klima HVAC Transformer 230 V to 24 V, 40 VA Primary voltage: 230 V, Secondary voltage: 24 V AC, Rating: 40 VA
- Klima HVAC Transformer 110 V to 24 V, 40 VA Primary voltage: 110/120 V, Secondary voltage: 24 V AC, Rating: 40 VA
- Klima HVAC Transformer 230 V to 24 V, 75 VA Primary voltage: 230 V, Secondary voltage: 24 V AC, Rating: 75 VA
- Klima HVAC Transformer 400 V to 24 V, 100 VA Primary voltage: 380/400 V, Secondary voltage: 24 V AC, Rating: 100 VA
Related products
Supply notes by country
How HVAC transformers are chosen and used in each country, with notes for its cities.
- Afghanistan
- Aland Islands
- Albania
- Algeria
- American Samoa
- Andorra
- Angola
- Anguilla
- Antigua and Barbuda
- Argentina
- Armenia
- Aruba
- Australia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bermuda
- Bhutan
- Bolivia
- Bonaire, Saint Eustatius and Saba
- Bosnia and Herzegovina
- Botswana
- Brazil
- British Virgin Islands
- Brunei
- Bulgaria
- Burkina Faso
- Burundi
- Cambodia
- Cameroon
- Canada
- Cape Verde
- Cayman Islands
- Central African Republic
- Chad
- Chile
- China
- Christmas Island
- Cocos Islands
- Colombia
- Comoros
- Cook Islands
- Costa Rica
- Croatia
- Cuba
- Curacao
- Cyprus
- Czech Republic
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- DR Congo
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Eswatini
- Ethiopia
- Falkland Islands
- Faroe Islands
- Fiji
- Finland
- France
- French Guiana
- French Polynesia
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Gibraltar
- Greece
- Greenland
- Grenada
- Guadeloupe
- Guam
- Guatemala
- Guernsey
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Honduras
- Hong Kong
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Isle of Man
- Israel
- Italy
- Ivory Coast
- Jamaica
- Japan
- Jersey
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macau
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Martinique
- Mauritania
- Mauritius
- Mayotte
- Mexico
- Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Montserrat
- Morocco
- Mozambique
- Myanmar
- Namibia
- Nauru
- Nepal
- New Caledonia
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Niue
- Norfolk Island
- North Korea
- North Macedonia
- Northern Mariana Islands
- Norway
- Oman
- Pakistan
- Palau
- Palestine
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Pitcairn
- Poland
- Portugal
- Puerto Rico
- Qatar
- Republic of the Congo
- Reunion
- Romania
- Russia
- Rwanda
- Saint Barthelemy
- Saint Helena
- Saint Martin
- Saint Pierre and Miquelon
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Sint Maarten
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Korea
- South Sudan
- Spain
- Sri Lanka
- St Kitts and Nevis
- St Lucia
- St Vincent and the Grenadines
- Sudan
- Suriname
- Svalbard and Jan Mayen
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- The Netherlands
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Turks and Caicos Islands
- Tuvalu
- U.S. Virgin Islands
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Vatican City
- Venezuela
- Vietnam
- Wallis and Futuna
- Western Sahara
- Yemen
- Zambia
- Zimbabwe
Key features
- Voltage options. Primary voltages for common 50 Hz and 60 Hz supplies with a 24 V AC secondary.
- VA ratings. A graded range so that you can match the total control load with headroom.
- Isolated secondary. Separates low-voltage control wiring from the mains.
- Thermal protection options. Fuses or thermal cut-outs on selected models.
- Easy mounting. Foot, plate or DIN mounting with flying leads or screw terminals, listed per model.
Where HVAC transformers are used
- 24 V control circuits in split and packaged air conditioners
- Thermostat, contactor and relay supplies
- Fan coil unit and zone valve power
- Chiller and AHU control panels
- Cold room and refrigeration controllers
- Heat pump control boards
- Building automation field devices
- Pump and fan control panels
- Lighting and signalling circuits in plant rooms
How to choose HVAC transformers
- Match the primary voltage and frequency to the local supply; a transformer rated for 60 Hz only can overheat on a 50 Hz supply, so check that the frequency rating covers yours.
- Add up the VA of all 24 V loads (coils, valves, controls) and choose a rating at least 20 % above the total.
- Check the secondary voltage the thermostat and contactors need; most HVAC controls use 24 V AC.
- Select protection to suit the panel design: fused primary or secondary, or a thermal cut-out.
- Check the mounting style and terminal layout against your panel space.
Care and maintenance
- Fit a fuse or breaker on the primary as the panel design requires, and a fuse on the secondary where the equipment manual calls for it.
- Tighten terminals and keep ventilation slots clear of dust.
- If a transformer runs hot or hums loudly, check for overload or a shorted coil before replacing it.
Common faults
- A control circuit that is dead although mains is present
- A hot, humming or smelling transformer
- A blown secondary fuse that keeps repeating
Questions about HVAC transformers
Why do HVAC systems use 24 V controls?
Low voltage makes thermostat wiring safer and easier to install, allows thin cable, and lets one standard voltage serve thermostats, contactors and valves.
How do I choose the VA rating?
Add up the VA draw of every load on the 24 V circuit, including contactor coils and valves, then add about 20 % spare capacity.
Can I replace a 40 VA transformer with a larger one?
Yes. A higher VA rating is safe because the load only draws what it needs, as long as voltages and frequency match. A lower VA rating can overheat.
What happens if a transformer is overloaded?
It runs hot, the voltage sags, relays chatter, and the winding may burn out or the fuse may blow.
Can I use a 50 Hz transformer on a 60 Hz supply?
Usually yes, since a 50 Hz design runs cooler on 60 Hz, but a 60 Hz-only transformer may overheat on 50 Hz. Check the frequency marking.
Is a transformer the same as a power supply?
A transformer only steps AC voltage down. A power supply also rectifies and regulates the output to DC.