Klima Industries

Klima HVAC Transformer 110 V to 24 V, 40 VA

Control transformer, 110/120 V primary, 24 V AC secondary, 40 VA.

Klima Transformer for HVAC ยท Model KTF-110-40

About this transformer

The KTF-110-40 is the same 40 VA control transformer wound for a 110/120 V primary, giving 24 V AC on the secondary. It is rated for 50 and 60 Hz, mounts on a plate and carries a thermal cut-out. On the secondary it can supply 1.67 A at 24 V. On the primary the same 40 VA draws about 0.36 A at 110 V and 0.33 A at 120 V, roughly twice the current of the 230 V model, so the supply wiring and fuse should be checked for that.

Supply voltage is where this model goes wrong. Its primary must not be connected to a 230 V supply, and the 230 V version must not be connected to 110/120 V. By the turns ratio, a 110/120 V transformer on 230 V would try to deliver roughly 46 to 50 V and overheat, while a 230 V transformer on 110/120 V would deliver only about 12 V. Measure the supply at the panel and read the nameplate before you connect. The sizing rule is the same as for the other models: add up the 24 V loads and choose a rating at least 20 % higher, which for 40 VA means loads of about 33 VA or less.

Specifications

SpecificationValue
ModelKTF-110-40
Primary voltage110/120 V
Secondary voltage24 V AC
Rating40 VA
Frequency50/60 Hz
MountingPlate
ProtectionThermal cut-out

Where it fits

  • Installations and imported equipment running on 110 or 120 V mains
  • Replacing a failed 40 VA control transformer on a 110/120 V unit
  • Panels that need 24 V AC for thermostats and contactors from a 110/120 V supply
  • Test benches and workshops that run 24 V controls from a 110/120 V supply

Fitting and checking

Isolate and lock off. Check the supply voltage with a meter, fix the transformer to the plate, connect the primary through a fuse or breaker chosen under the panel rules (it draws about 0.36 A at 110 V when fully loaded) and connect the secondary to the 24 V circuit. Measure the secondary under load, because an unloaded transformer reads high. If the thermal cut-out has opened, look for an overloaded or shorted 24 V circuit first.

Compared with the other HVAC transformers

This model is one of 4 in Klima Transformer for HVAC; what changes from one to the next is primary voltage and rating. Every model in the family has the same secondary voltage (24 V AC), frequency (50/60 Hz), mounting (Plate) and protection (Thermal cut-out), so the choice comes down to the values above.

SpecificationThis modelAcross the range
Primary voltage110/120 V230 V / 110/120 V / 380/400 V
Rating40 VA40 to 100 VA

This is the smallest model in the range by rating. The next step up is Klima HVAC Transformer 230 V to 24 V, 75 VA (75 VA). Quote the model code KTF-110-40 when you enquire so that the right size is supplied.

Questions

Can I use it on a 230 V supply?

No. The primary is for 110/120 V. For a 230 V supply use the KTF-230-40.

Why does the 50/60 Hz rating matter?

A transformer rated for 60 Hz only can overheat on a 50 Hz supply. This model is rated for both, so the frequency of your supply does not limit its use.

Selection, care and fault-finding notes for the whole family are on the Klima Transformer for HVAC page, and the contact page takes enquiries with the model code KTF-110-40. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.