Klima Industries

HVAC transformers supply in Grenada

Home to about 111,000 people, Grenada sits in North America. Its capital is St. George's. Grenada has a hot and humid tropical climate, with little variation across its small area. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of HVAC transformers in Grenada are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Grenada for a quotation.

Capital
St. George's
Population
111,000
Area
344 km²
Time zone
UTC-4 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
St. George's
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Transformer for HVAC models

All Klima products for Grenada · Klima Transformer for HVAC overview

What Grenada demands of HVAC transformers

In Grenada, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed HVAC transformers and keep control boxes closed with their gaskets intact.

Heat is the main enemy of electrical parts here: HVAC transformers run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

With a 230 V, 50 Hz supply, Grenada follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every transformer against the equipment it serves.

Cities that buy HVAC transformers in Grenada

The directory lists one city for Grenada: Saint George's, with about 7,500 people, although the capital, St. George's, is not among the listed cities. Orders from anywhere in Grenada are best quoted against it. With a single listed city, the stocking plan for Grenada follows one set of conditions, a hot and humid tropical climate in Saint George's. In Saint George's, expect moisture on terminals and corrosion to show first on HVAC transformers.

Size and settlement in Grenada

The directory puts Grenada at about 344 km², the 33rd smallest of its 241 countries, a little smaller than the U.S. Virgin Islands (352 km²). With 111,000 residents the average density is 324 per km², so Grenada counts as densely settled, denser than 83% of the other countries in this directory. The land area is small, so road distances on any one island are short; for island groups, say which island a delivery is for. Its population is similar to that of Micronesia (113,000).

Where HVAC transformers are used in Grenada

In Grenada, these are the jobs that most often call for HVAC transformers:

  • Thermostat, contactor and relay supplies
  • 24 V control circuits in split and packaged air conditioners
  • Fan coil unit and zone valve power
  • Building automation field devices
  • Lighting and signalling circuits in plant rooms

Klima HVAC transformers models

ModelPrimary voltage (V)Secondary voltage (V)Rating (VA)
Klima HVAC Transformer 230 V to 24 V, 40 VA230 V24 V AC40
Klima HVAC Transformer 110 V to 24 V, 40 VA110/120 V24 V AC40
Klima HVAC Transformer 230 V to 24 V, 75 VA230 V24 V AC75
Klima HVAC Transformer 400 V to 24 V, 100 VA380/400 V24 V AC100

See the full Klima Transformer for HVAC range for specifications, standards and a plain-language guide to choosing the right part.

How to pick HVAC transformers for work in Grenada

  • Match the primary voltage and frequency to the local supply; a transformer rated for 60 Hz only can overheat on a 50 Hz supply, so check that the frequency rating covers yours.
  • Check the secondary voltage the thermostat and contactors need; most HVAC controls use 24 V AC.
  • Confirm the supply first: Grenada uses 230 V at 50 Hz, so check the voltage and frequency rating of HVAC transformers against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Grenada that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Care and maintenance in Grenada

  • Tighten terminals and keep ventilation slots clear of dust.

A tropical climate keeps cooling demand steady through the year in Grenada, so there is no quiet season. Schedule checks of HVAC transformers around the main rainy-season changes and keep spares on hand. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Signs of trouble

  • A blown secondary fuse that keeps repeating

Approvals for HVAC transformers sold into Grenada

Klima HVAC transformers are specified against IEC 61558-1 and IEC 61558-2-2 (safety transformers, control transformers). For import and installation in Grenada, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Supply and delivery to Grenada

Sea freight into Grenada normally clears through ports such as St. George's, with onward delivery by road; urgent parts can travel by air.

The local currency is the Dollar (XCD), so confirm the quotation currency and delivery terms before you order. The main languages are English; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about HVAC transformers in Grenada

What happens if a transformer is overloaded?

It runs hot, the voltage sags, relays chatter, and the winding may burn out or the fuse may blow.

What voltage should HVAC transformers be rated for in Grenada?

Grenada supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so HVAC transformers rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to HVAC transformers in Grenada?

Klima HVAC transformers follow IEC 61558-1 and IEC 61558-2-2 (safety transformers, control transformers). In Grenada the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are HVAC transformers delivered to Grenada?

Cargo for Grenada usually arrives through St. George's; tell us your preferred port or delivery address with your enquiry.

Which city in Grenada can I order HVAC transformers for?

Saint George's (7,500) is the one city listed for Grenada, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.

What local time and daylight should I plan for in Grenada?

Saint George's keeps UTC-4 all year. At 12.1° N there are about 12 h 50 min of daylight in June and about 11 h 25 min in December.

More Klima products for Grenada

HVAC transformers in cities across Grenada