Klima Industries

Klima HVAC transformers for Turkey

Turkey is a large national market in Asia, and its capital is Ankara. Most of the country has a Mediterranean climate, and conditions vary by region. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.

Demand for HVAC transformers comes mostly from offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Turkey.

Capital
Ankara
Population
82.3 million
Area
780,580 km²
Time zone
UTC+3 all year
Climate
Mediterranean
Supply
230 V, 50 Hz
Main ports
Ambarli (Istanbul), Mersin Port, Izmir Alsancak Port
Standards
CE marking and TSE conformity

Klima Transformer for HVAC models

All Klima products for Turkey · Klima Transformer for HVAC overview

What Turkey demands of HVAC transformers

In Turkey, cooling demand peaks from late spring to early autumn. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; HVAC transformers with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of HVAC transformers during each seasonal service.

Turkey supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so HVAC transformers rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

HVAC transformers across the cities of Turkey

The three largest listed cities (Istanbul, Ankara and Bursa) hold about 47% of the people living in listed cities, which means demand is shared between a few large centres and many smaller cities. The capital is Ankara, but the biggest listed city is Istanbul, about 352 km away to the west of it; quote the delivery city on every enquiry. These are the biggest listed cities in Turkey; the last column names what to watch for in HVAC transformers there.

CityPeopleClimateWhat wears HVAC transformers first
Istanbul15.7 millionMediterraneanterminals loosening and parts running hot
Ankara3.5 millioncontinentalbrittle insulation and hard starting
Bursa3.1 millionMediterraneanterminals loosening and parts running hot
Diyarbakir1.8 millionMediterraneanexpansion and contraction loosening joints
Adana1.8 millionMediterraneanterminals loosening and parts running hot
Konya1.4 millionMediterraneanterminals loosening and parts running hot

Voltage next door: Turkey and its neighbours

Across the border, Syria, Georgia, Iraq, Iran, Greece and 3 more also run on a nominal 230 V at 50 Hz, so ratings carry over between Turkey and its neighbours; the nameplate of the equipment still decides.

The sun and the clock in Turkey

Ankara keeps UTC+3 all year.

Ankara lies at 39.9° N, 32.9° E. Daylight lasts about 15 h 00 min at the June solstice and about 9 h 20 min in December, with a noon sun 74° and 27° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat.

Where HVAC transformers are used in Turkey

HVAC transformers are most often specified in Turkey for:

  • Fan coil unit and zone valve power
  • Building automation field devices
  • Thermostat, contactor and relay supplies
  • 24 V control circuits in split and packaged air conditioners
  • Chiller and AHU control panels

Klima HVAC transformers models

ModelPrimary voltage (V)Secondary voltage (V)Rating (VA)
Klima HVAC Transformer 230 V to 24 V, 40 VA230 V24 V AC40
Klima HVAC Transformer 110 V to 24 V, 40 VA110/120 V24 V AC40
Klima HVAC Transformer 230 V to 24 V, 75 VA230 V24 V AC75
Klima HVAC Transformer 400 V to 24 V, 100 VA380/400 V24 V AC100

See the full Klima Transformer for HVAC range for specifications, standards and a plain-language guide to choosing the right part.

Choosing HVAC transformers for Turkey

  • Select protection to suit the panel design: fused primary or secondary, or a thermal cut-out.
  • Check the secondary voltage the thermostat and contactors need; most HVAC controls use 24 V AC.
  • Confirm the supply first: Turkey uses 230 V at 50 Hz, so check the voltage and frequency rating of HVAC transformers against the equipment nameplate.
  • For Mediterranean conditions in Turkey, favour higher temperature ratings and some margin on every rated value.

Keeping HVAC transformers reliable in Turkey

  • If a transformer runs hot or hums loudly, check for overload or a shorted coil before replacing it.

Turkey lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of HVAC transformers for April or May, ahead of that peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • A hot, humming or smelling transformer

Standards and paperwork for HVAC transformers in Turkey

Klima HVAC transformers follow IEC 61558-1 and IEC 61558-2-2 (safety transformers, control transformers). In Turkey, the local framework is CE marking and TSE conformity, so match the datasheet to both and ask for any conformity documents your project needs.

Supply and delivery to Turkey

Cargo for Turkey usually arrives through Ambarli (Istanbul), Mersin Port and Izmir Alsancak Port; tell us your preferred port or delivery address with your enquiry.

The local currency is the Lira (TRY), so confirm the quotation currency and delivery terms before you order. The main languages are Turkish, Kurdish, Dimli and Azerbaijani; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

HVAC transformers in Turkey: common questions

How do I choose the VA rating?

Add up the VA draw of every load on the 24 V circuit, including contactor coils and valves, then add about 20 % spare capacity.

What voltage should HVAC transformers be rated for in Turkey?

The mains supply in Turkey is 230 V, 50 Hz. Match HVAC transformers to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to HVAC transformers in Turkey?

Klima HVAC transformers follow IEC 61558-1 and IEC 61558-2-2 (safety transformers, control transformers). In Turkey the local framework is CE marking and TSE conformity; request the datasheet and conformity documents with your enquiry.

How are HVAC transformers delivered to Turkey?

Sea freight into Turkey normally clears through ports such as Ambarli (Istanbul), Mersin Port and Izmir Alsancak Port, with onward delivery by road; urgent parts can travel by air.

Which cities in Turkey can I order HVAC transformers for?

Every listed city is covered. The largest are Istanbul (15.7 million), Ankara (3.5 million), Bursa (3.1 million), Izmir (2.9 million) and Gaziantep (2.2 million). The country page lists the rest.

Do the neighbours of Turkey use the same mains supply?

Yes. All 8 listed neighbours (Syria, Georgia, Iraq, Iran, Greece and 3 more) run on a nominal 230 V at 50 Hz, the same as Turkey, so the electrical rating of a part does not usually change at the border.

What local time and daylight should I plan for in Turkey?

Ankara keeps UTC+3 all year. At 39.9° N there are about 15 h 00 min of daylight in June and about 9 h 20 min in December.

More Klima products for Turkey

HVAC transformers in cities across Turkey