Klima Industries

Klima Delay on Make Timer

Restarting a compressor immediately after it stops forces it to start against high discharge pressure, which overloads the motor, trips protectors and shortens life. A delay on make timer inserts a short wait, commonly a few minutes, between the thermostat's call for cooling and the compressor contactor energising. It also staggers the restart of several units after a power outage so they do not all draw starting current at once.

Klima Delay on Make Timers are compact modules that wire in series with the contactor coil or control signal. The model list shows supply voltage, delay range, output contact rating and mounting style, so one part can be specified for single-phase, rooftop and cold room installations.

A Klima Delay on Make (DOM) Timer holds the compressor off for a set period after power is applied or after the thermostat re-closes. The delay lets refrigerant pressures equalise and keeps compressors from restarting against high head pressure.

Models

Related products

Supply notes by country

How delay on make timers are chosen and used in each country, with notes for its cities.

Key features

  • Delay ranges. Fixed and adjustable delays from seconds to several minutes.
  • Supply voltages. 24 V AC/DC and mains-voltage versions for different control circuits.
  • Output contacts. Relay contact ratings listed for direct switching of contactor coils.
  • Mounting styles. Plug-in and surface-mounted bodies for different control boxes.
  • Power-restore protection. Delays the restart after outages and brown-outs.

Where delay on make timers are used

  • Split and ducted air conditioners
  • Rooftop packaged units
  • Cold rooms and refrigeration condensing units
  • Staggered start of several compressors after power cuts
  • Chiller control panels
  • Refrigerated trucks and containers
  • Pump and fan motor delayed start
  • Vending machines and display fridges
  • Generator-backed sites with mains transfer switching

How to choose delay on make timers

  • Set the delay to the compressor maker's recommended off-time; three to five minutes is typical for hermetic compressors.
  • Match the supply voltage to the control circuit; 24 V AC is common on thermostat circuits.
  • Check the output contact rating against the contactor coil's holding and inrush current.
  • Choose an adjustable delay when one timer must serve several equipment types.
  • Check the mounting style: plug-in socket, surface mount or panel.

Care and maintenance

  • Test the delay after installation by cycling the thermostat and timing the restart.
  • Keep the timer away from heat sources inside the panel.
  • Replace the timer if the delay drifts or fails to latch.

Common faults

  • A compressor that restarts immediately after switching off
  • Repeated overload trips or clicking contactors
  • No restart at all after the delay period has passed

Questions about delay on make timers

What does a delay on make timer do?

It delays the closing of its output contact for a set time after power or a start signal is applied, so equipment restarts only after a safe interval.

Why do compressors need a delay?

Immediately after shutdown the high and low side pressures are still unequal, so a restart is difficult and can overload the motor.

How long should the delay be?

Follow the compressor manufacturer's guidance. Around three to five minutes is common for hermetic air conditioning and refrigeration compressors.

Is it the same as an anti-short-cycle device?

An anti-short-cycle timer is a specific use of a delay on make timer. It prevents restarting until the minimum off-time has elapsed.

Can one timer protect several compressors?

Usually each compressor circuit needs its own delay. One timer can sequence several only if its output rating and logic are designed for that.

Where do I wire a delay on make timer?

In series with the contactor coil circuit, or between the thermostat output and the contactor coil, according to the wiring diagram supplied.

Guides for delay on make timers