Klima Industries

Klima Delay on Make Timer in Papua New Guinea

With about 8.6 million people, Papua New Guinea is a mid-sized market in Oceania. Its capital is Port Moresby. Most of the country has a hot and humid tropical climate, and conditions vary by region. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of delay on make timers in Papua New Guinea are offices, shops and malls, factories and workshops as well as hospitals and clinics. The range below has 4 models; send an enquiry with the model code and your delivery address in Papua New Guinea.

Capital
Port Moresby
Population
8.6 million
Area
462,840 km²
Time zone
UTC+10 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
Port Moresby, Lae
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Delay on Make Timer models

All Klima products for Papua New Guinea · Klima Delay on Make Timer overview

What Papua New Guinea demands of delay on make timers

In Papua New Guinea, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed delay on make timers and keep control boxes closed with their gaskets intact.

In very hot weather a badly placed control keeps the compressor running; mount delay on make timers out of direct sun and away from heat sources.

The mains supply in Papua New Guinea is 230 V, 50 Hz. Match delay on make timers to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Cities that buy delay on make timers in Papua New Guinea

From Arawa to Daru, the longest straight-line gap between listed cities is about 1,398 km; so delivery to the far end of the country is a long road journey. About 64% of the people in listed cities live in Port Moresby, Lae and Arawa; a few centres do most of the buying. These are the biggest listed cities in Papua New Guinea; the last column names what to watch for in delay on make timers there.

CityPeopleClimateWhat wears delay on make timers first
Port Moresby284,000hot and humid tropicalcondensation inside enclosures
Lae76,000hot and humid tropicalcondensation inside enclosures
Arawa40,000hot and humid tropicalsensor drift and setpoints creeping
Mount Hagen34,000hot and humid tropicalsensor drift and setpoints creeping
Madang27,000hot and humid tropicalcondensation inside enclosures
Kokopo26,000hot and humid tropicalsensor drift and setpoints creeping

All 13 listed cities share a hot and humid tropical climate, so one stocking plan covers the whole country.

Papua New Guinea in numbers

The directory puts Papua New Guinea at about 462,840 km², the 55th largest of its 241 countries, a little smaller than Cameroon (475,440 km²). Population density averages 19 people per km² across 8.6 million residents, which is sparsely settled and sparser than 83% of the other countries in this directory. With long distances between sites, a call-out for a missing part is costly, so keep a small stock of the common ratings. For scale, Switzerland has a similar number of people (8.5 million).

Voltage next door: Papua New Guinea and its neighbours

Papua New Guinea borders Indonesia. That country uses a nominal 230 V at 50 Hz, the same as Papua New Guinea, so an electrical rating that fits one side of the border fits the other.

Where delay on make timers are used in Papua New Guinea

Delay on make timers are most often specified in Papua New Guinea for:

  • Rooftop packaged units
  • Split and ducted air conditioners
  • Chiller control panels
  • Cold rooms and refrigeration condensing units
  • Staggered start of several compressors after power cuts

Klima delay on make timers models

ModelSupply voltage (V)Delay rangeContact rating (A)
Klima Delay on Make Timer, Fixed, 24 V AC/DC24 V AC/DC3 min fixed5
Klima Delay on Make Timer, Fixed, 230 V AC230 V AC3 min fixed5
Klima Delay on Make Timer, Adjustable, 24 V AC/DC24 V AC/DC0.1 to 10 min5
Klima Delay on Make Timer, Adjustable, 230 V AC230 V AC0.1 to 10 min5

See the full Klima Delay on Make Timer range for specifications, standards and a plain-language guide to choosing the right part.

Choosing delay on make timers for Papua New Guinea

  • Match the supply voltage to the control circuit; 24 V AC is common on thermostat circuits.
  • Set the delay to the compressor maker's recommended off-time; three to five minutes is typical for hermetic compressors.
  • Confirm the supply first: Papua New Guinea uses 230 V at 50 Hz, so check the voltage and frequency rating of delay on make timers against the equipment nameplate.
  • For hot and humid tropical conditions in Papua New Guinea, favour sealed, corrosion-resistant construction.

Care and maintenance in Papua New Guinea

  • Test the delay after installation by cycling the thermostat and timing the restart.

With little seasonal change in temperature, air conditioning in Papua New Guinea works almost every day. Spread checks of delay on make timers through the year instead of waiting for a peak. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Faults to watch for

  • Repeated overload trips or clicking contactors

Approvals for delay on make timers sold into Papua New Guinea

Klima delay on make timers are specified against IEC 61812-1 (time relays). For import and installation in Papua New Guinea, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Supply and delivery to Papua New Guinea

Sea freight into Papua New Guinea normally clears through ports such as Port Moresby and Lae, with onward delivery by road; urgent parts can travel by air.

The local currency is the Kina (PGK), so confirm the quotation currency and delivery terms before you order. The main languages are English, Hiri Motu, Motu and Tok Pisin; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Delay on make timers in Papua New Guinea: common questions

Why do compressors need a delay?

Immediately after shutdown the high and low side pressures are still unequal, so a restart is difficult and can overload the motor.

What voltage should delay on make timers be rated for in Papua New Guinea?

With a 230 V, 50 Hz supply, Papua New Guinea follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every delay on make timer against the equipment it serves.

Which standards apply to delay on make timers in Papua New Guinea?

Klima delay on make timers follow IEC 61812-1 (time relays). In Papua New Guinea the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are delay on make timers delivered to Papua New Guinea?

Cargo for Papua New Guinea usually arrives through Port Moresby and Lae; tell us your preferred port or delivery address with your enquiry.

Which cities in Papua New Guinea can I order delay on make timers for?

Every listed city is covered. The largest are Port Moresby (284,000), Lae (76,000), Arawa (40,000), Mount Hagen (34,000) and Popondetta (28,000). The country page lists the rest.

What local time and daylight should I plan for in Papua New Guinea?

Port Moresby keeps UTC+10 all year. At 9.5° S there are about 11 h 34 min of daylight in June and about 12 h 41 min in December.

Do the neighbours of Papua New Guinea use the same mains supply?

Yes. Its only listed neighbour (Indonesia) runs on a nominal 230 V at 50 Hz, the same as Papua New Guinea, so the electrical rating of a part does not usually change at the border.

More Klima products for Papua New Guinea

Delay on make timers in cities across Papua New Guinea