Klima Delay on Make Timer, Adjustable, 230 V AC
Adjustable delay on make timer on 230 V AC; holds the compressor off for 0.1 to 10 min after power or a thermostat call.
Klima Delay on Make Timer ยท Model KDM-230A
About this delay on make timer
This is the adjustable timer for mains-voltage control: a 230 V AC supply, a delay from 0.1 to 10 minutes, a 5 A contact and a plug-in or surface mount. It is the one to use when several units on a site must restart at different times after a power cut: set each timer to a different delay and the starting currents arrive in sequence rather than all at once, so the supply is not overloaded as the building comes back.
A common arrangement for a plant of four compressors is to set the first at 3 minutes and the others a minute or two apart, but the right values depend on the equipment's minimum off time and on the supply capacity. Because the coil circuit is at mains voltage, wire and label it clearly, and keep it separate from low-voltage control cables.
Specifications
| Specification | Value |
|---|---|
| Model | KDM-230A |
| Supply voltage | 230 V AC |
| Delay range | 0.1 to 10 min |
| Contact rating | 5 A |
| Mounting | Plug-in / surface |
Where it fits
- Staggered restart of several condensing units after a power failure
- Cold-room and process plant with a 230 V control circuit
- Staging of fans and pumps behind a main contactor
- Replacement for an adjustable on-delay relay on 230 V control
Fitting and checking
With the supply isolated, wire the timer across the 230 V control supply, and put its output contact in series with the contactor coil. Set the delay, restore power and time the load with a stopwatch. Record the setting for each unit on a drawing or schedule so that the sequence is documented, and check it again after any change to the plant.
Compared with the other delay on make timers
The 4 models in Klima Delay on Make Timer differ mainly in supply voltage and delay range. Every model in the family has the same contact rating (5 A) and mounting (Plug-in / surface), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Supply voltage | 230 V AC | 24 V AC/DC / 230 V AC |
| Delay range | 0.1 to 10 min | 3 min fixed / 0.1 to 10 min |
The closest alternative in the range is Klima Delay on Make Timer, Fixed, 230 V AC, which shares 3 of the 4 listed specifications and differs in delay range. Quote the model code KDM-230A when you enquire.
Questions
How do I choose the delay for each unit?
Start with each compressor's minimum off time, normally three minutes, then add steps between units so the largest starting currents do not overlap. The electrical supply's capacity limits how many can start together.
Why should I label the setting?
A delay that has been altered during fault-finding is a common cause of units that restart at the wrong time. A label shows the intended setting.
Selection, care and fault-finding notes for the whole family are on the Klima Delay on Make Timer page, and the contact page takes enquiries with the model code KDM-230A. For background reading, see the guide Contactor sizing for compressors: poles, current and coil voltage.