Klima Industries

Contactors for Papua New Guinea

Home to about 8.6 million people, Papua New Guinea sits in Oceania. Its capital is Port Moresby. The prevailing climate is hot and humid tropical, though conditions differ between regions. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Demand for contactors comes mostly from offices, shops and malls as well as factories and workshops. The Klima range includes 7 models, each with a specification table; send an enquiry from Papua New Guinea for a quotation.

Capital
Port Moresby
Population
8.6 million
Area
462,840 km²
Time zone
UTC+10 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
Port Moresby, Lae
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Contactors models

All Klima products for Papua New Guinea · Klima Contactors overview

Contactors and the climate in Papua New Guinea

In Papua New Guinea, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

With a 230 V, 50 Hz supply, Papua New Guinea follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

Cities that buy contactors in Papua New Guinea

Port Moresby is both the capital and the largest listed city, with about 284,000 people, so the capital is also the biggest single market. About 64% of the people in listed cities live in Port Moresby, Lae and Arawa; a few centres do most of the buying. Climate decides how contactors age, and it changes from city to city in Papua New Guinea: the last column shows what to expect.

CityPeopleClimateWhat wears contactors first
Port Moresby284,000hot and humid tropicalmoisture on terminals and corrosion
Lae76,000hot and humid tropicalmoisture on terminals and corrosion
Arawa40,000hot and humid tropicalterminals loosening and parts running hot
Madang27,000hot and humid tropicalterminals loosening and parts running hot
Kimbe19,000hot and humid tropicalmoisture on terminals and corrosion
Goroka19,000hot and humid tropicalmoisture on terminals and corrosion

All 13 listed cities share a hot and humid tropical climate, so one stocking plan covers the whole country.

Daylight, sun angle and time in Papua New Guinea

Local time in Port Moresby is UTC+10 all year. Across Papua New Guinea the listed cities use 2 standard time zones (UTC+10 to UTC+11); give the delivery city so the right local hours apply.

Port Moresby lies at 9.5° S, 147.2° E. Daylight lasts about 11 h 34 min at the June solstice and about 12 h 41 min in December, with a noon sun 57° and 76° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

The land and the people of Papua New Guinea

At roughly 462,840 km², Papua New Guinea is the 55th largest of the 241 countries covered by this directory, a little smaller than Cameroon (475,440 km²). Its 8.6 million people give an average of 19 per km². In this directory that is sparsely settled, sparser than 83% of the other countries in this directory. Sites can be a long way apart, so it is worth ordering a full set of spares for the season rather than one part at a time. For scale, Switzerland has a similar number of people (8.5 million).

Jobs in Papua New Guinea that call for contactors

Typical work in Papua New Guinea that needs contactors:

  • Chiller and air handling unit starter panels
  • Compressor control in split and packaged air conditioners
  • Condenser fan switching
  • Lighting and general power switching in plant rooms
  • Heat pump defrost and reversing controls

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick contactors for work in Papua New Guinea

  • Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
  • Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
  • Confirm the supply first: Papua New Guinea uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Papua New Guinea that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Keeping contactors reliable in Papua New Guinea

  • Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.

With little seasonal change in temperature, air conditioning in Papua New Guinea works almost every day. Spread checks of contactors through the year instead of waiting for a peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Signs of trouble

  • Burnt or welded contacts that keep the unit running when switched off

Standards and paperwork for contactors in Papua New Guinea

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters); in Papua New Guinea expect applicable national electrical-safety and import conformity rules (generally IEC-based) as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering contactors for Papua New Guinea

Sea freight into Papua New Guinea normally clears through ports such as Port Moresby and Lae, with onward delivery by road; urgent parts can travel by air.

The local currency is the Kina (PGK), so confirm the quotation currency and delivery terms before you order. The main languages are English, Hiri Motu, Motu and Tok Pisin; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Contactors in Papua New Guinea: common questions

Why does my contactor buzz?

Buzzing usually means low coil voltage, a dirty or worn magnetic core or a loose connection. Measure the voltage at the coil while the unit is calling for cooling.

What voltage should contactors be rated for in Papua New Guinea?

Papua New Guinea supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to contactors in Papua New Guinea?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Papua New Guinea the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Papua New Guinea?

Cargo for Papua New Guinea usually arrives through Port Moresby and Lae; tell us your preferred port or delivery address with your enquiry.

Which cities in Papua New Guinea can I order contactors for?

Every listed city is covered. The largest are Port Moresby (284,000), Lae (76,000), Arawa (40,000), Mount Hagen (34,000) and Popondetta (28,000). The country page lists the rest.

What local time and daylight should I plan for in Papua New Guinea?

Port Moresby keeps UTC+10 all year. At 9.5° S there are about 11 h 34 min of daylight in June and about 12 h 41 min in December.

Do the neighbours of Papua New Guinea use the same mains supply?

Yes. Its only listed neighbour (Indonesia) runs on a nominal 230 V at 50 Hz, the same as Papua New Guinea, so the electrical rating of a part does not usually change at the border.

More Klima products for Papua New Guinea

Contactors in cities across Papua New Guinea