Klima Industries

Buying delay on make timers in South Africa

South Africa is a large national market in Africa, and its capital is Pretoria. Most of the country has a highland climate, and conditions vary by region. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.

Demand for delay on make timers comes mostly from offices, shops and malls, factories and workshops as well as data centres and server rooms. The range below has 4 models; send an enquiry with the model code and your delivery address in South Africa.

Capital
Pretoria
Population
57.8 million
Area
1,219,912 km²
Time zone
UTC+2 all year
Climate
Highland
Supply
230 V, 50 Hz
Main ports
Durban, Cape Town, Ngqura
Standards
NRCS / SABS compulsory specifications

Klima Delay on Make Timer models

All Klima products for South Africa · Klima Delay on Make Timer overview

Conditions in South Africa that affect delay on make timers

In South Africa, cooling demand is moderate, and refrigeration and process loads stay steady all year. Thinner air reduces convective cooling, so delay on make timers in outdoor panels run warmer than the same part at sea level; derate where the datasheet advises it.

Wide temperature variation makes differentials matter; recheck the setting of delay on make timers so that the compressor does not short-cycle.

The mains supply in South Africa is 230 V, 50 Hz. Match delay on make timers to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Cities that buy delay on make timers in South Africa

Together Johannesburg, Cape Town and Durban account for roughly 52% of the population of all listed cities, so demand is shared between a few large centres and many smaller cities. The capital is Pretoria, but the biggest listed city is Johannesburg, about 53 km away to the south of it; quote the delivery city on every enquiry. The table lists the largest cities in South Africa with the climate stress that wears delay on make timers fastest in each.

CityPeopleClimateWhat wears delay on make timers first
Johannesburg9.4 millionhighlandcalibration drift between seasons
Cape Town4.8 millionMediterraneancalibration drift between seasons
Durban3.3 millionhumid subtropicalsensor drift and setpoints creeping
Pretoria2.1 millionhighlandcalibration drift between seasons
Gqeberha1.1 millionhumid subtropicalcondensation inside enclosures
Pietermaritzburg839,000humid subtropicalsensor drift and setpoints creeping

The 38 listed cities fall into 3 climate types (19 highland, 16 humid subtropical and 3 Mediterranean), so parts are best chosen for the city where they will run.

Mains supply across the borders of South Africa

South Africa borders Zimbabwe, Eswatini, Mozambique, Botswana, Namibia and Lesotho. All of them use a nominal 230 V at 50 Hz, the same as South Africa, so an electrical rating that fits one side of the border fits the other.

Time zone, sun and daylight in South Africa

Pretoria keeps UTC+2 all year.

Sunlight at 25.7° S (Pretoria): about 10 h 32 min of daylight in June, about 13 h 45 min in December, and a noon sun that reaches 41° in June and 88° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Typical uses of delay on make timers in South Africa

In South Africa, these are the jobs that most often call for delay on make timers:

  • Chiller control panels
  • Staggered start of several compressors after power cuts
  • Cold rooms and refrigeration condensing units
  • Generator-backed sites with mains transfer switching
  • Split and ducted air conditioners

Klima delay on make timers models

ModelSupply voltage (V)Delay rangeContact rating (A)
Klima Delay on Make Timer, Fixed, 24 V AC/DC24 V AC/DC3 min fixed5
Klima Delay on Make Timer, Fixed, 230 V AC230 V AC3 min fixed5
Klima Delay on Make Timer, Adjustable, 24 V AC/DC24 V AC/DC0.1 to 10 min5
Klima Delay on Make Timer, Adjustable, 230 V AC230 V AC0.1 to 10 min5

See the full Klima Delay on Make Timer range for specifications, standards and a plain-language guide to choosing the right part.

Choosing delay on make timers for South Africa

  • Check the output contact rating against the contactor coil's holding and inrush current.
  • Match the supply voltage to the control circuit; 24 V AC is common on thermostat circuits.
  • Confirm the supply first: South Africa uses 230 V at 50 Hz, so check the voltage and frequency rating of delay on make timers against the equipment nameplate.
  • For highland conditions in South Africa, allow extra rating margin for thin air.

Keeping delay on make timers reliable in South Africa

  • Replace the timer if the delay drifts or fails to latch.

Altitude moderates the heat in South Africa, but the load follows the dry and rainy seasons and the sun. Check delay on make timers at the change of season and keep spares for peak periods. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Signs of trouble

  • Repeated overload trips or clicking contactors

Approvals for delay on make timers sold into South Africa

Klima delay on make timers are specified against IEC 61812-1 (time relays). For import and installation in South Africa, buyers also meet NRCS / SABS compulsory specifications. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Ordering delay on make timers for South Africa

Sea freight into South Africa normally clears through ports such as Durban, Cape Town and Ngqura, with onward delivery by road; urgent parts can travel by air.

The local currency is the Rand (ZAR), so confirm the quotation currency and delivery terms before you order. The main languages are Zulu, Xhosa, Afrikaans and Pedi; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about delay on make timers in South Africa

Why do compressors need a delay?

Immediately after shutdown the high and low side pressures are still unequal, so a restart is difficult and can overload the motor.

What voltage should delay on make timers be rated for in South Africa?

With a 230 V, 50 Hz supply, South Africa follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every delay on make timer against the equipment it serves.

Which standards apply to delay on make timers in South Africa?

Klima delay on make timers follow IEC 61812-1 (time relays). In South Africa the local framework is NRCS / SABS compulsory specifications; request the datasheet and conformity documents with your enquiry.

How are delay on make timers delivered to South Africa?

Cargo for South Africa usually arrives through Durban, Cape Town and Ngqura; tell us your preferred port or delivery address with your enquiry.

Which cities in South Africa can I order delay on make timers for?

Every listed city is covered. The largest are Johannesburg (9.4 million), Cape Town (4.8 million), Durban (3.3 million), Pretoria (2.1 million) and Soweto (1.7 million). The country page lists the rest.

What local time and daylight should I plan for in South Africa?

Pretoria keeps UTC+2 all year. At 25.7° S there are about 10 h 32 min of daylight in June and about 13 h 45 min in December.

Do the neighbours of South Africa use the same mains supply?

Yes. All 6 listed neighbours (Zimbabwe, Eswatini, Mozambique, Botswana, Namibia and Lesotho) run on a nominal 230 V at 50 Hz, the same as South Africa, so the electrical rating of a part does not usually change at the border.

More Klima products for South Africa

Delay on make timers in cities across South Africa