Klima Industries

Delay on make timers supply in Guadeloupe

Guadeloupe is a compact market in North America, and its capital is Basse-Terre. Across Guadeloupe the climate is hot and humid tropical, and conditions are similar from place to place. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of delay on make timers in Guadeloupe are offices, shops and malls, factories and workshops as well as hospitals and clinics. The Klima range includes 4 models, each with a specification table; send an enquiry from Guadeloupe for a quotation.

Capital
Basse-Terre
Population
443,000
Area
1,780 km²
Time zone
UTC-4 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
Pointe-a-Pitre
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Delay on Make Timer models

All Klima products for Guadeloupe · Klima Delay on Make Timer overview

Conditions in Guadeloupe that affect delay on make timers

In Guadeloupe, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit delay on make timers with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Sun-warmed walls make thermostats read high; place delay on make timers on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.

The mains supply in Guadeloupe is 230 V, 50 Hz. Match delay on make timers to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Delay on make timers across the cities of Guadeloupe

Basse-Terre, the capital, lies about 39 km south-west of Les Abymes, which is the largest listed city, so say which of the two cities a delivery is for. Together Les Abymes, Baie-Mahault and Le Gosier account for roughly 48% of the population of all listed cities, so there are a few big markets and a long tail of smaller ones. The table lists the largest cities in Guadeloupe with the climate stress that wears delay on make timers fastest in each.

CityPeopleClimateWhat wears delay on make timers first
Les Abymes54,000hot and humid tropicalcondensation inside enclosures
Baie-Mahault31,000hot and humid tropicalcondensation inside enclosures
Le Gosier29,000hot and humid tropicalcondensation inside enclosures
Petit-Bourg25,000hot and humid tropicalsensor drift and setpoints creeping
Sainte-Anne23,000hot and humid tropicalcondensation inside enclosures
Le Moule23,000hot and humid tropicalcondensation inside enclosures

Every one of the 9 listed cities has a hot and humid tropical climate, which keeps the choice of parts consistent from city to city.

Size and settlement in Guadeloupe

At roughly 1,780 km², Guadeloupe is the 60th smallest of the 241 countries covered by this directory. With 443,000 residents the average density is 249 per km², so Guadeloupe counts as densely settled, denser than 78% of the other countries in this directory. The land area is small, so road distances on any one island are short; for island groups, say which island a delivery is for. Its population is similar to that of Martinique (433,000).

Time zone, sun and daylight in Guadeloupe

Local time in Basse-Terre is UTC-4 all year.

At 16.0° N, Basse-Terre has about 13 h 05 min of daylight at the June solstice and about 11 h 10 min at the December solstice. The noon sun stands 83° above the horizon in June and 51° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

Typical uses of delay on make timers in Guadeloupe

Typical work in Guadeloupe that needs delay on make timers:

  • Rooftop packaged units
  • Chiller control panels
  • Split and ducted air conditioners
  • Generator-backed sites with mains transfer switching
  • Staggered start of several compressors after power cuts

Klima delay on make timers models

ModelSupply voltage (V)Delay rangeContact rating (A)
Klima Delay on Make Timer, Fixed, 24 V AC/DC24 V AC/DC3 min fixed5
Klima Delay on Make Timer, Fixed, 230 V AC230 V AC3 min fixed5
Klima Delay on Make Timer, Adjustable, 24 V AC/DC24 V AC/DC0.1 to 10 min5
Klima Delay on Make Timer, Adjustable, 230 V AC230 V AC0.1 to 10 min5

See the full Klima Delay on Make Timer range for specifications, standards and a plain-language guide to choosing the right part.

Selecting delay on make timers in Guadeloupe

  • Choose an adjustable delay when one timer must serve several equipment types.
  • Check the output contact rating against the contactor coil's holding and inrush current.
  • Confirm the supply first: Guadeloupe uses 230 V at 50 Hz, so check the voltage and frequency rating of delay on make timers against the equipment nameplate.
  • For hot and humid tropical conditions in Guadeloupe, favour sealed, corrosion-resistant construction.

Keeping delay on make timers reliable in Guadeloupe

  • Keep the timer away from heat sources inside the panel.

With little seasonal change in temperature, air conditioning in Guadeloupe works almost every day. Spread checks of delay on make timers through the year instead of waiting for a peak. Controls drift over time; verify setpoints and switch points before the demanding months.

Signs of trouble

  • Repeated overload trips or clicking contactors

Standards and paperwork for delay on make timers in Guadeloupe

Klima delay on make timers follow IEC 61812-1 (time relays); in Guadeloupe expect applicable national electrical-safety and import conformity rules (generally IEC-based) as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering delay on make timers for Guadeloupe

Cargo for Guadeloupe usually arrives through Pointe-a-Pitre; tell us your preferred port or delivery address with your enquiry.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are French; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Delay on make timers in Guadeloupe: common questions

How long should the delay be?

Follow the compressor manufacturer's guidance. Around three to five minutes is common for hermetic air conditioning and refrigeration compressors.

What voltage should delay on make timers be rated for in Guadeloupe?

With a 230 V, 50 Hz supply, Guadeloupe follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every delay on make timer against the equipment it serves.

Which standards apply to delay on make timers in Guadeloupe?

Klima delay on make timers follow IEC 61812-1 (time relays). In Guadeloupe the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are delay on make timers delivered to Guadeloupe?

Sea freight into Guadeloupe normally clears through ports such as Pointe-a-Pitre, with onward delivery by road; urgent parts can travel by air.

Which cities in Guadeloupe can I order delay on make timers for?

Every listed city is covered. The largest are Les Abymes (54,000), Baie-Mahault (31,000), Le Gosier (29,000), Petit-Bourg (25,000) and Sainte-Anne (23,000). The country page lists the rest.

What local time and daylight should I plan for in Guadeloupe?

Basse-Terre keeps UTC-4 all year. At 16.0° N there are about 13 h 05 min of daylight in June and about 11 h 10 min in December.

More Klima products for Guadeloupe

Delay on make timers in cities across Guadeloupe