Klima Industries

Klima Delay on Make Timer in the U.S. Virgin Islands

Home to about 107,000 people, the U.S. Virgin Islands sits in North America. Its capital is Charlotte Amalie. The U.S. Virgin Islands has a hot and humid tropical climate, with little variation across its small area. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of delay on make timers in the U.S. Virgin Islands are offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in the U.S. Virgin Islands.

Capital
Charlotte Amalie
Population
107,000
Area
352 km²
Time zone
UTC-4 all year
Climate
Hot and humid tropical
Supply
120 V, 60 Hz
Standards
UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States

Klima Delay on Make Timer models

All Klima products for the U.S. Virgin Islands · Klima Delay on Make Timer overview

Conditions in the U.S. Virgin Islands that affect delay on make timers

In the U.S. Virgin Islands, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed delay on make timers and keep control boxes closed with their gaskets intact.

Sun-warmed walls make thermostats read high; place delay on make timers on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.

The U.S. Virgin Islands supplies 120 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of delay on make timers against the nameplate.

Delay on make timers across the cities of the U.S. Virgin Islands

The largest listed city is Saint Croix, not the capital: Charlotte Amalie is roughly 71 km to its north, and orders should name the right one. These are the biggest listed cities in the U.S. Virgin Islands; the last column names what to watch for in delay on make timers there.

CityPeopleClimateWhat wears delay on make timers first
Saint Croix51,000hot and humid tropicalsensor drift and setpoints creeping
Charlotte Amalie20,000hot and humid tropicalsensor drift and setpoints creeping

How large is the U.S. Virgin Islands, and how is it settled?

By land area the U.S. Virgin Islands is the 34th smallest of the 241 places listed here, at roughly 352 km², a little larger than Grenada (344 km²). About 107,000 people live there, an average of 304 people per km², which makes it densely settled, denser than 82% of the other countries in this directory. With so little land, distances inside the country are short, but an enquiry should still name the city or island for delivery. In population it sits close to Aruba, which has about 106,000.

Typical uses of delay on make timers in the U.S. Virgin Islands

Delay on make timers are most often specified in the U.S. Virgin Islands for:

  • Split and ducted air conditioners
  • Chiller control panels
  • Rooftop packaged units
  • Cold rooms and refrigeration condensing units
  • Staggered start of several compressors after power cuts

Klima delay on make timers models

ModelSupply voltage (V)Delay rangeContact rating (A)
Klima Delay on Make Timer, Fixed, 24 V AC/DC24 V AC/DC3 min fixed5
Klima Delay on Make Timer, Fixed, 230 V AC230 V AC3 min fixed5
Klima Delay on Make Timer, Adjustable, 24 V AC/DC24 V AC/DC0.1 to 10 min5
Klima Delay on Make Timer, Adjustable, 230 V AC230 V AC0.1 to 10 min5

See the full Klima Delay on Make Timer range for specifications, standards and a plain-language guide to choosing the right part.

Choosing delay on make timers for the U.S. Virgin Islands

  • Check the mounting style: plug-in socket, surface mount or panel.
  • Check the output contact rating against the contactor coil's holding and inrush current.
  • Confirm the supply first: the U.S. Virgin Islands uses 120 V at 60 Hz, so check the voltage and frequency rating of delay on make timers against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in the U.S. Virgin Islands that usually means UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States.

Care and maintenance in the U.S. Virgin Islands

  • Keep the timer away from heat sources inside the panel.

With little seasonal change in temperature, air conditioning in the U.S. Virgin Islands works almost every day. Spread checks of delay on make timers through the year instead of waiting for a peak. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Signs of trouble

  • No restart at all after the delay period has passed

Which standards apply to delay on make timers in the U.S. Virgin Islands

Klima delay on make timers follow IEC 61812-1 (time relays). In the U.S. Virgin Islands, the local framework is UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States, so match the datasheet to both and ask for any conformity documents your project needs.

Supply and delivery to the U.S. Virgin Islands

Freight reaches the U.S. Virgin Islands by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.

The local currency is the Dollar (USD), so confirm the quotation currency and delivery terms before you order. The main languages are English; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about delay on make timers in the U.S. Virgin Islands

How long should the delay be?

Follow the compressor manufacturer's guidance. Around three to five minutes is common for hermetic air conditioning and refrigeration compressors.

What voltage should delay on make timers be rated for in the U.S. Virgin Islands?

The supply in the U.S. Virgin Islands is 120 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a delay on make timer.

Which standards apply to delay on make timers in the U.S. Virgin Islands?

Klima delay on make timers follow IEC 61812-1 (time relays). In the U.S. Virgin Islands the local framework is UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States; request the datasheet and conformity documents with your enquiry.

How are delay on make timers delivered to the U.S. Virgin Islands?

Freight reaches the U.S. Virgin Islands by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.

Which cities in the U.S. Virgin Islands can I order delay on make timers for?

Every listed city is covered. The largest are Saint Croix (51,000) and Charlotte Amalie (20,000). The country page lists the rest.

What local time and daylight should I plan for in the U.S. Virgin Islands?

Charlotte Amalie keeps UTC-4 all year. At 18.3° N there are about 13 h 14 min of daylight in June and about 11 h 02 min in December.

More Klima products for the U.S. Virgin Islands

Delay on make timers in cities across the U.S. Virgin Islands