Klima capacitors for China
China is one of the largest national markets in the world in Asia, and its capital is Beijing. The prevailing climate is humid subtropical, though conditions differ between regions. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
Demand for capacitors comes mostly from offices, shops and malls as well as factories and workshops. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in China.
- Capital
- Beijing
- Population
- 1.4 billion
- Area
- 9,596,960 km²
- Time zone
- UTC+8 all year
- Climate
- Humid subtropical
- Supply
- 230 V, 50 Hz
- Main ports
- Shanghai Port, Ningbo-Zhoushan Port, Shenzhen Port, Guangzhou (Nansha) Port
- Standards
- CCC certification for regulated electrical products
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for China · Klima Capacitors overview
Capacitors and the climate in China
In China, cooling demand peaks through a long, humid summer. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
With a 230 V, 50 Hz supply, China follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Cities that buy capacitors in China
The largest listed city is Shanghai, not the capital: Beijing is roughly 1,068 km to its north-west, and orders should name the right one. The three largest listed cities (Shanghai, Beijing and Shenzhen) hold about 18% of the people living in listed cities, which means demand is spread across many cities. The table lists the largest cities in China with the climate stress that wears capacitors fastest in each.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Shanghai | 24.9 million | humid subtropical | moisture on terminals and corrosion |
| Beijing | 19 million | continental | expansion and contraction loosening joints |
| Shenzhen | 17.5 million | humid subtropical | terminals loosening and parts running hot |
| Tianjin | 11.1 million | continental | expansion and contraction loosening joints |
| Wuhan | 10.4 million | humid subtropical | moisture on terminals and corrosion |
| Xi'an | 9.6 million | humid subtropical | moisture on terminals and corrosion |
Climate changes from city to city: of the 60 listed cities, 38 humid subtropical and 22 continental, so spares chosen for one city may not suit another.
Voltage next door: China and its neighbours
China borders Laos, Bhutan, Tajikistan, Kazakhstan, Mongolia and 3 more. All of them use a nominal 230 V at 50 Hz, the same as China, so an electrical rating that fits one side of the border fits the other.
How large is China, and how is it settled?
At roughly 9,596,960 km², China is the 4th largest of the 241 countries covered by this directory, almost exactly the size of the United States (9,629,091 km²). Population density averages 147 people per km² across 1.4 billion residents, which is densely settled and denser than 67% of the other countries in this directory. Most sites sit within reach of a city, so deliveries can usually be planned city by city. In population it sits close to India, which has about 1.4 billion.
Typical uses of capacitors in China
Typical work in China that needs capacitors:
- Fan coil unit and blower motors
- Chiller and air-cooled condenser fans
- Commercial display fridges and freezers
- Heat pump outdoor units
- Ventilation and exhaust fan motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in China
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: China uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in China that usually means CCC certification for regulated electrical products.
Care and maintenance in China
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check capacitors in China. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Which standards apply to capacitors in China
Klima capacitors follow IEC 60252-1 (AC motor capacitors); in China expect CCC certification for regulated electrical products as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.
Getting capacitors to China
Sea freight into China normally clears through ports such as Shanghai Port, Ningbo-Zhoushan Port, Shenzhen Port and Guangzhou (Nansha) Port, with onward delivery by road; urgent parts can travel by air.
The local currency is the Yuan Renminbi (CNY), so confirm the quotation currency and delivery terms before you order. The main languages are Chinese, Yue Chinese, Wu Chinese and Daur; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in China
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in China?
China supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Which standards apply to capacitors in China?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In China the local framework is CCC certification for regulated electrical products; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to China?
Cargo for China usually arrives through Shanghai Port, Ningbo-Zhoushan Port, Shenzhen Port and Guangzhou (Nansha) Port; tell us your preferred port or delivery address with your enquiry.
Which cities in China can I order capacitors for?
Every listed city is covered. The largest are Shanghai (24.9 million), Beijing (19 million), Shenzhen (17.5 million), Guangzhou (16.1 million) and Chengdu (13.6 million). The country page lists the rest.
Do the neighbours of China use the same mains supply?
Yes. All 8 listed neighbours (Laos, Bhutan, Tajikistan, Kazakhstan, Mongolia and 3 more) run on a nominal 230 V at 50 Hz, the same as China, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in China?
Beijing keeps UTC+8 all year. At 39.9° N there are about 15 h 00 min of daylight in June and about 9 h 20 min in December.
More Klima products for China
- Klima Contactors in China
- Klima Terminal Crimps in China
- Klima Transformer for HVAC in China
- Klima PVC Tapes in China
- Klima Cables (3 & 4 Core) in China
- Klima Filter Driers in China