Klima Capacitors in Thailand
Thailand is a large national market in Asia, and its capital is Bangkok. Most of the country has a hot and humid tropical climate, and conditions vary by region. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Thailand are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Thailand are welcome.
- Capital
- Bangkok
- Population
- 69.4 million
- Area
- 514,000 km²
- Time zone
- UTC+7 all year
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
- Main ports
- Laem Chabang Port, Bangkok Port
- Standards
- TISI standards for regulated products
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Thailand · Klima Capacitors overview
Capacitors and the climate in Thailand
In Thailand, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
With a 230 V, 50 Hz supply, Thailand follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Cities that buy capacitors in Thailand
The capital, Bangkok, is also the largest listed city (about 5.1 million people), which keeps most large buyers in one place. From Yala to Chiang Rai, the longest straight-line gap between listed cities is about 1,495 km; so allow extra road time for the far end of the country. These are the biggest listed cities in Thailand; the last column names what to watch for in capacitors there.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Bangkok | 5.1 million | hot and humid tropical | terminals loosening and parts running hot |
| Chonburi | 219,000 | hot and humid tropical | moisture on terminals and corrosion |
| Hat Yai | 192,000 | hot and humid tropical | terminals loosening and parts running hot |
| Khlong Sam Wa | 169,000 | hot and humid tropical | moisture on terminals and corrosion |
| Lampang | 156,000 | hot and humid tropical | moisture on terminals and corrosion |
| Kabin Buri | 140,000 | hot and humid tropical | moisture on terminals and corrosion |
Every one of the 41 listed cities has a hot and humid tropical climate, which keeps the choice of parts consistent from city to city.
Neighbouring supplies to check before ordering capacitors
Thailand borders Laos, Myanmar, Cambodia and Malaysia. All of them use a nominal 230 V at 50 Hz, the same as Thailand, so an electrical rating that fits one side of the border fits the other.
Time zone, sun and daylight in Thailand
Local time in Bangkok is UTC+7 all year.
Bangkok lies at 13.8° N, 100.5° E. Daylight lasts about 12 h 56 min at the June solstice and about 11 h 19 min in December, with a noon sun 80° and 53° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.
Typical uses of capacitors in Thailand
Typical work in Thailand that needs capacitors:
- Fan coil unit and blower motors
- Packaged rooftop units and ducted systems
- Condensing units for walk-in cold rooms
- Heat pump outdoor units
- Chiller and air-cooled condenser fans
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Thailand
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Confirm the supply first: Thailand uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For hot and humid tropical conditions in Thailand, favour sealed, corrosion-resistant construction.
Care and maintenance in Thailand
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
With little seasonal change in temperature, air conditioning in Thailand works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- A swollen, bulging or leaking case
Standards and paperwork for capacitors in Thailand
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Thailand, the local framework is TISI standards for regulated products, so match the datasheet to both and ask for any conformity documents your project needs.
Ordering capacitors for Thailand
Sea freight into Thailand normally clears through ports such as Laem Chabang Port and Bangkok Port, with onward delivery by road; urgent parts can travel by air.
The local currency is the Baht (THB), so confirm the quotation currency and delivery terms before you order. The main languages are Thai and English; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Thailand: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Thailand?
Thailand supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Which standards apply to capacitors in Thailand?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Thailand the local framework is TISI standards for regulated products; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Thailand?
Cargo for Thailand usually arrives through Laem Chabang Port and Bangkok Port; tell us your preferred port or delivery address with your enquiry.
Which cities in Thailand can I order capacitors for?
Every listed city is covered. The largest are Bangkok (5.1 million), Chonburi (219,000), Hat Yai (192,000), Si Racha (179,000) and Latkrabang (174,000). The country page lists the rest.
Do the neighbours of Thailand use the same mains supply?
Yes. All 4 listed neighbours (Laos, Myanmar, Cambodia and Malaysia) run on a nominal 230 V at 50 Hz, the same as Thailand, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Thailand?
Bangkok keeps UTC+7 all year. At 13.8° N there are about 12 h 56 min of daylight in June and about 11 h 19 min in December.
More Klima products for Thailand
- Klima Contactors in Thailand
- Klima Terminal Crimps in Thailand
- Klima Transformer for HVAC in Thailand
- Klima Temperature Controllers in Thailand
- Klima Drier Core 48-KL in Thailand
- Klima Delay on Make Timer in Thailand