Klima Industries

Klima CBB65 Run Capacitor 5 µF

CBB65 run capacitor, 5 µF. Its reactance is about 637 ? at 50 Hz. Quote the voltage you need with your enquiry.

Klima Capacitors · Model KC-C65-5

About this capacitor

The CBB65 series is the one to choose for run duty on air-conditioning compressors and condenser fans, and this 5 µF version is one of 8 single-section sizes Klima lists. Match the µF value to the motor nameplate and the voltage to the figure on the old can.

At 5 µF this part is number 2 of 8 in the CBB65 run capacitors (3 to 60 µF). The µF value should match the motor nameplate closely: a capacitor that is much too small leaves the motor short of torque, and one that is much too large pushes the winding current above its design figure.

Specifications

SpecificationValue
ModelKC-C65-5
Capacitance5 µF
TypeSingle run

Where it fits

  • Fan motors in dehumidifiers and portable air conditioners
  • Service work where a single-section part is needed beside a separate fan or compressor capacitor
  • Condenser fan motors on small split and window air conditioners
  • Indoor blower and fan-coil motors that list a small run capacitor on the nameplate

Fitting and checking

Before replacing a 5 µF capacitor, confirm the fault. A fan or compressor that hums but will not start, or that starts slowly and runs hot, points to a weak capacitor, while a bulged or leaking case is a certain failure. After fitting, check that the motor current is within the nameplate value and listen for a smooth start.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance and type.

SpecificationThis modelAcross the range
Capacitance5 µF0.5 to 480 µF
TypeSingle runSingle run, Dual run, Start, Start/run

In the KC-C65 series, the next step down by capacitance is Klima CBB65 Run Capacitor 3 µF (3 µF) and the next step up is Klima CBB65 Run Capacitor 6 µF (6 µF). Quote the model code KC-C65-5 when you enquire so that the right size is supplied.

Questions

What is the next size up or down from 5 µF?

Within the CBB65 run capacitors the next size down is 3 µF and the next size up is 6 µF. Quote the voltage you need with the enquiry, because the voltage rating is confirmed from the old capacitor.

How often should a run capacitor like this be replaced?

There is no fixed interval. Heat and electrical stress wear a capacitor gradually, so replace it when a capacitance reading falls outside tolerance or the case bulges or leaks. On outdoor units in hot climates a yearly check at service time is sensible.

How do I tell whether the 5 µF capacitor has failed?

Typical signs are a motor that hums and will not start, a fan that turns slowly or only when pushed, a compressor that trips on overload, or a case that is swollen or leaking. To confirm, isolate and discharge the part and read it with a capacitance meter: a value below about 4.5 µF on a 5 µF capacitor means it has lost capacity.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-C65-5. For background reading, see the guide How to choose a run capacitor for an air conditioner.