Klima CBB65 Run Capacitor 5 µF
CBB65 run capacitor, 5 µF. Its reactance is about 637 ? at 50 Hz. Quote the voltage you need with your enquiry.
Klima Capacitors · Model KC-C65-5
About this capacitor
The CBB65 series is the one to choose for run duty on air-conditioning compressors and condenser fans, and this 5 µF version is one of 8 single-section sizes Klima lists. Match the µF value to the motor nameplate and the voltage to the figure on the old can.
At 5 µF this part is number 2 of 8 in the CBB65 run capacitors (3 to 60 µF). The µF value should match the motor nameplate closely: a capacitor that is much too small leaves the motor short of torque, and one that is much too large pushes the winding current above its design figure.
Specifications
| Specification | Value |
|---|---|
| Model | KC-C65-5 |
| Capacitance | 5 µF |
| Type | Single run |
Where it fits
- Fan motors in dehumidifiers and portable air conditioners
- Service work where a single-section part is needed beside a separate fan or compressor capacitor
- Condenser fan motors on small split and window air conditioners
- Indoor blower and fan-coil motors that list a small run capacitor on the nameplate
Fitting and checking
Before replacing a 5 µF capacitor, confirm the fault. A fan or compressor that hums but will not start, or that starts slowly and runs hot, points to a weak capacitor, while a bulged or leaking case is a certain failure. After fitting, check that the motor current is within the nameplate value and listen for a smooth start.
Compared with the other capacitors
The 116 models in Klima Capacitors differ mainly in capacitance and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 5 µF | 0.5 to 480 µF |
| Type | Single run | Single run, Dual run, Start, Start/run |
In the KC-C65 series, the next step down by capacitance is Klima CBB65 Run Capacitor 3 µF (3 µF) and the next step up is Klima CBB65 Run Capacitor 6 µF (6 µF). Quote the model code KC-C65-5 when you enquire so that the right size is supplied.
Questions
What is the next size up or down from 5 µF?
Within the CBB65 run capacitors the next size down is 3 µF and the next size up is 6 µF. Quote the voltage you need with the enquiry, because the voltage rating is confirmed from the old capacitor.
How often should a run capacitor like this be replaced?
There is no fixed interval. Heat and electrical stress wear a capacitor gradually, so replace it when a capacitance reading falls outside tolerance or the case bulges or leaks. On outdoor units in hot climates a yearly check at service time is sensible.
How do I tell whether the 5 µF capacitor has failed?
Typical signs are a motor that hums and will not start, a fan that turns slowly or only when pushed, a compressor that trips on overload, or a case that is swollen or leaking. To confirm, isolate and discharge the part and read it with a capacitance meter: a value below about 4.5 µF on a 5 µF capacitor means it has lost capacity.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-C65-5. For background reading, see the guide How to choose a run capacitor for an air conditioner.