Klima Motor Start Capacitor 36-43 µF 250 V
Motor start capacitor with 36-43 µF capacity and a 250 V rating. It is typically fitted to small pumps and compressors.
Klima Capacitors · Model KC-MS-36-43
About this capacitor
Klima's 36-43 µF, 250 V start capacitor is built for short, repeated starting duty rather than for continuous running. The range figure is how start capacitors are specified: any reading inside 36 to 43 µF is a part performing as intended.
Voltage class: 250 V. This class is commonly specified for motors on 220-240 V supplies. Match the rating on the original, and use a higher class if the exact one is not to hand.
Specifications
| Specification | Value |
|---|---|
| Model | KC-MS-36-43 |
| Capacitance | 36-43 µF |
| Rated voltage | 250 VAC |
| Type | Start |
Where it fits
- Pump sets that trip their overload on start because the start capacitor has lost capacity
- Motors on 220-240 V supplies that specify a 250 V start capacitor
- Small capacitor-start motors on water pumps and fountain pumps
- Bench grinders, drills and small workshop machines with single-phase motors
Fitting and checking
Never fit a start capacitor as a run capacitor, and never leave it in circuit after the motor has started. If the motor does not drop the capacitor out, a start capacitor in the 36-43 µF range will overheat and may split its case within minutes.
Compared with the other capacitors
This model is one of 116 in Klima Capacitors; what changes from one to the next is capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 36-43 µF | 0.5 to 480 µF |
| Rated voltage | 250 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start | Single run, Dual run, Start, Start/run |
In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 31-40 µF 250 V (31-40 µF) and the next step up is Klima Motor Start Capacitor 40-48 µF 250 V (40-48 µF). Quote the model code KC-MS-36-43 when you enquire so that the right size is supplied.
Questions
Which ranges sit either side of 36-43 µF?
Among the 250 V start capacitors the next range down is 31-40 µF and the next range up is 40-48 µF. Quote the range and the voltage class when you enquire.
Can a start capacitor be used as a run capacitor?
No. Start capacitors are built for brief, intermittent duty and overheat when left in circuit. A motor that needs a capacitor all the time needs a run capacitor of the µF value on its nameplate, from the run capacitors in this family.
Why does a start capacitor fail so often?
It works hard for a very short time. Heat from repeated starts, a supply that sags and prolongs starting, and a relay that holds the capacitor in circuit are the usual causes. A 36-43 µF part that has failed once should prompt a check of the relay or switch before the replacement goes in.