Klima Industries

Klima Capacitors in Ethiopia

With about 109.2 million people, Ethiopia is one of the largest national markets in the world in Africa. Its capital is Addis Ababa. The prevailing climate is highland, though conditions differ between regions. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.

Demand for capacitors comes mostly from offices, shops and malls as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Ethiopia for a quotation.

Capital
Addis Ababa
Population
109.2 million
Area
1,127,127 km²
Time zone
UTC+3 all year
Climate
Highland
Supply
230 V, 50 Hz
Standards
Ethiopian Standards Agency (ESA) requirements

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Ethiopia · Klima Capacitors overview

Conditions in Ethiopia that affect capacitors

In Ethiopia, cooling demand is moderate, and refrigeration and process loads stay steady all year. Thinner air reduces convective cooling, so capacitors in outdoor panels run warmer than the same part at sea level; derate where the datasheet advises it.

Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.

With a 230 V, 50 Hz supply, Ethiopia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.

Capacitors across the cities of Ethiopia

About 39% of the people in listed cities live in Addis Ababa, Jijiga and Gonder; no single city dominates the market. The capital, Addis Ababa, is also the largest listed city (about 3.9 million people), which keeps most large buyers in one place. These are the biggest listed cities in Ethiopia; the last column names what to watch for in capacitors there.

CityPeopleClimateWhat wears capacitors first
Addis Ababa3.9 millionhighlandexpansion and contraction loosening joints
Jijiga483,000hot and humid tropicalterminals loosening and parts running hot
Gonder466,000hot and humid tropicalmoisture on terminals and corrosion
Bahir Dar350,000hot and humid tropicalmoisture on terminals and corrosion
Dire Dawa343,000hot and humid tropicalterminals loosening and parts running hot
Dessie270,000hot and humid tropicalterminals loosening and parts running hot

Local conditions differ across the 50 listed cities (49 hot and humid tropical and 1 highland), and the right part depends on which city it is for.

Daylight, sun angle and time in Ethiopia

Local time in Addis Ababa is UTC+3 all year.

At 9.0° N, Addis Ababa has about 12 h 39 min of daylight at the June solstice and about 11 h 36 min at the December solstice. The noon sun stands 76° above the horizon in June and 58° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Neighbouring supplies to check before ordering capacitors

Across the border, Eritrea, Kenya, Sudan, South Sudan, Somalia and Djibouti also run on a nominal 230 V at 50 Hz, so ratings carry over between Ethiopia and its neighbours; the nameplate of the equipment still decides.

Where capacitors are used in Ethiopia

Typical work in Ethiopia that needs capacitors:

  • Split and window air conditioners
  • Heat pump outdoor units
  • Fan coil unit and blower motors
  • Commercial display fridges and freezers
  • Condensing units for walk-in cold rooms

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round45 + 7.5440 / 370Dual run
Klima Motor Start Capacitor 64-77 µF 250 V64-77250Start
Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case216-259110 / 125Start
Klima CBB61 Start/Run Capacitor 4 µF 500 V AC4500Start/run
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Ethiopia

  • Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
  • Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
  • Confirm the supply first: Ethiopia uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Ethiopia that usually means Ethiopian Standards Agency (ESA) requirements.

Keeping capacitors reliable in Ethiopia

  • Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.

Altitude moderates the heat in Ethiopia, but the load follows the dry and rainy seasons and the sun. Check capacitors at the change of season and keep spares for peak periods. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • A swollen, bulging or leaking case

Which standards apply to capacitors in Ethiopia

Two sets of rules apply to capacitors sold into Ethiopia: the product standard, IEC 60252-1 (AC motor capacitors), and the local one, Ethiopian Standards Agency (ESA) requirements. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.

Getting capacitors to Ethiopia

As a landlocked market, Ethiopia receives sea freight through a transit port in a neighbouring country (Eritrea, Kenya, Sudan and South Sudan); air freight is the faster option for urgent parts.

The local currency is the Birr (ETB), so confirm the quotation currency and delivery terms before you order. The main languages are Amharic, English, Oromo and Tigrinya; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Ethiopia: common questions

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

What voltage should capacitors be rated for in Ethiopia?

Ethiopia supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to capacitors in Ethiopia?

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Ethiopia the local framework is Ethiopian Standards Agency (ESA) requirements; request the datasheet and conformity documents with your enquiry.

How are capacitors delivered to Ethiopia?

Ethiopia has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Eritrea, Kenya, Sudan and South Sudan and continues inland by road or rail; allow extra time for transit and border handling.

Which cities in Ethiopia can I order capacitors for?

Every listed city is covered. The largest are Addis Ababa (3.9 million), Jijiga (483,000), Gonder (466,000), Mek'ele (458,000) and Nazret (457,000). The country page lists the rest.

What local time and daylight should I plan for in Ethiopia?

Addis Ababa keeps UTC+3 all year. At 9.0° N there are about 12 h 39 min of daylight in June and about 11 h 36 min in December.

Do the neighbours of Ethiopia use the same mains supply?

Yes. All 6 listed neighbours (Eritrea, Kenya, Sudan, South Sudan, Somalia and Djibouti) run on a nominal 230 V at 50 Hz, the same as Ethiopia, so the electrical rating of a part does not usually change at the border.

More Klima products for Ethiopia

Capacitors in cities across Ethiopia