Klima Capacitors supplied to Gonder
Found in Ethiopia, Gonder is a mid-sized city with a hot and humid tropical climate. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Gonder are offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Gonder for a quotation.
- Country
- Ethiopia
- Population
- 466,000
- Climate
- Hot and humid tropical
- Coordinates
- 12.6° N, 37.5° E
- Time zone
- UTC+3 all year
- From Addis Ababa
- 421 km north
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Gonder · Klima Capacitors overview
Capacitors and the climate in Gonder
In Gonder, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Capacitors in Gonder and the cities near it
By population Gonder is 3rd of the 50 cities listed for Ethiopia, with roughly 3.8% of their combined population, about 12% of the size of Addis Ababa, the largest. From Addis Ababa, the capital, Gonder is roughly 421 km to the north. It is about the same size as Kanazawa in Japan, which has 466,000.
Nearest to Gonder: Debre Tabor (103 km south-east), Bahir Dar (112 km south) and Inda Silase (189 km north-east). No other listed city lies within 100 km, and 12 lie within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Debre Tabor | 103 km south-east | 125,000 | moisture on terminals and corrosion |
| Bahir Dar | 112 km south | 350,000 | terminals loosening and parts running hot |
| Inda Silase | 189 km north-east | 100,000 | moisture on terminals and corrosion |
| Aksum | 217 km north-east | 95,000 | moisture on terminals and corrosion |
| Alamata | 228 km east | 70,000 | terminals loosening and parts running hot |
| Adwa | 233 km north-east | 86,000 | moisture on terminals and corrosion |
A mid-sized city like Gonder may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Daylight and sun angle in Gonder
Local time in Gonder is UTC+3 all year.
Gonder lies at 12.6° N, 37.5° E. Daylight lasts about 12 h 52 min at the June solstice and about 11 h 23 min in December, with a noon sun 79° and 54° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Unlike the highland country as a whole, Gonder is hot and humid tropical; 48 other listed cities share it.
Typical uses of capacitors in Gonder
In Gonder, these are the jobs that most often call for capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Gonder
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Ask for the datasheet and the documents your project needs; in Ethiopia that usually means Ethiopian Standards Agency (ESA) requirements.
Keeping capacitors reliable in Gonder
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
A tropical climate keeps cooling demand steady through the year in Gonder, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Gonder
To order capacitors for Gonder, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Ethiopia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Gonder
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Gonder?
With a 230 V, 50 Hz supply, Ethiopia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Gonder?
Shipments for Gonder normally clear customs at one of the main entry points of Ethiopia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Gonder can I order for?
Enquiries are welcome from every part of Gonder. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Gonder?
Gonder keeps UTC+3 all year. At 12.6° N there are about 12 h 52 min of daylight in June and about 11 h 23 min in December.
Which cities near Gonder can the same order serve?
The listed cities closest to Gonder are Debre Tabor (103 km south-east), Bahir Dar (112 km south) and Inda Silase (189 km north-east). Combine them into one order and give each delivery address.
More Klima products for Gonder
- Klima Contactors in Gonder
- Klima Terminal Crimps in Gonder
- Klima Transformer for HVAC in Gonder
- Klima Cables (3 & 4 Core) in Gonder
- Klima Temperature Controllers in Gonder
- Klima Copper Coils & Tubes in Gonder