Klima Dual Run Capacitor 25+5 µF 440/370 V, Round
Dual run capacitor for motors that need 25+5 µF at 440/370 V, in a round case. Quote model code KC-DR-25-5 when you enquire.
Klima Capacitors · Model KC-DR-25-5
About this capacitor
Two capacitors share one can in the 25+5 µF dual run part: 25 µF between the common and compressor terminals, 5 µF between the common and fan terminals. The round case is rated 440/370 V and the listing covers 50/60 Hz equipment.
Each section has its own tolerance window. For a ±5 % part the 25 µF section should measure between 23.75 and 26.25 µF and the 5 µF section between 4.75 and 5.25 µF; for ±10 % the windows are 22.5 to 27.5 µF and 4.5 to 5.5 µF.
Specifications
| Specification | Value |
|---|---|
| Model | KC-DR-25-5 |
| Capacitance | 25 + 5 µF |
| Rated voltage | 440 / 370 VAC |
| Type | Dual run |
| Case | Round |
| Frequency | 50/60 Hz |
Where it fits
- Outdoor fans that stop or run slowly while the compressor still runs, a sign that the small section is weak
- Service vans that stock one dual-rated can per size instead of separate 370 V and 440 V parts
- Heat-pump outdoor units, where one can serves the compressor and the fan in both modes
- Condensing units for cold rooms and commercial refrigeration with single-phase motors
Fitting and checking
Measure each section of the old can before ordering: C to HERM should be near 25 µF and C to FAN near 5 µF. A low reading on either section means the can is finished. Fit the 25+5 µF replacement in the same bracket, tighten it so the case cannot rotate, and check that every connector is tight.
Compared with the other capacitors
Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 25 + 5 µF | 0.5 to 480 µF |
| Rated voltage | 440 / 370 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Dual run | Single run, Dual run, Start, Start/run |
| Case | Round | Round, Oval, Oval aluminium, Round phenolic |
In the KC-DR series, the next step down by capacitance is Klima Dual Run Capacitor 10 µF 440/370 V, Round (10 µF) and the next step up is Klima Dual Run Capacitor 40+3 µF 440/370 V, Round (40 + 3 µF). Quote the model code KC-DR-25-5 when you enquire so that the right size is supplied.
Questions
What is the next size up or down from 25+5 µF?
Within the 440/370 V dual run capacitors the next pairing down is 10 µF and the next pairing up is 40+3 µF. Both values and the dual 440/370 V rating are matched in the enquiry.
Can I use two single capacitors instead of this dual part?
In principle yes: a 25 µF and a 5 µF single run capacitor of the right voltage rating can replace one dual can, if each is wired the way the can's terminals were. Most technicians prefer one dual part because it needs one bracket and fewer connections.
Can a weak dual capacitor damage the compressor?
It can. A compressor that runs on a capacitor well below its rated value draws extra current and heats up, which ages the windings and shortens compressor life. If either section of a 25+5 µF can reads clearly low, replace the can promptly.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-DR-25-5. For background reading, see the guide How to choose a run capacitor for an air conditioner.