Capacitors for Denmark
With about 5.8 million people, Denmark is a mid-sized market in Europe. Its capital is Copenhagen. The prevailing climate is temperate, though conditions differ between regions. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
The main users of capacitors in Denmark are offices, shops and malls, homes and apartments as well as cold stores and food distribution. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Denmark.
- Capital
- Copenhagen
- Population
- 5.8 million
- Area
- 43,094 km²
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- Climate
- Temperate
- Supply
- 230 V, 50 Hz
- Main ports
- Aarhus
- Standards
- CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Denmark · Klima Capacitors overview
Capacitors and the climate in Denmark
In Denmark, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
The mains supply in Denmark is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Mapping demand for capacitors in Denmark
The two listed cities furthest apart, Copenhagen and Esbjerg, are about 260 km from each other in a straight line, so most deliveries inside the country stay within a day of road. The three largest listed cities (Copenhagen, Arhus and Odense) hold about 65% of the people living in listed cities, which means a few centres do most of the buying. Climate decides how capacitors age, and it changes from city to city in Denmark: the last column shows what to expect.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Copenhagen | 1.2 million | temperate | moisture on terminals and corrosion |
| Arhus | 285,000 | temperate | expansion and contraction loosening joints |
| Odense | 181,000 | temperate | moisture on terminals and corrosion |
| Esbjerg | 72,000 | temperate | moisture on terminals and corrosion |
| Randers | 63,000 | temperate | expansion and contraction loosening joints |
| Kolding | 62,000 | temperate | expansion and contraction loosening joints |
How large is Denmark, and how is it settled?
Denmark covers about 43,094 km², the 107th smallest of the 241 countries in this directory, a little larger than the Netherlands (41,526 km²). Its 5.8 million people give an average of 135 per km². In this directory that is densely settled, denser than 63% of the other countries in this directory. Customers are rarely far from a city, so a delivery plan by city is normally enough. For scale, Turkmenistan has a similar number of people (5.9 million).
Mains supply across the borders of Denmark
Denmark borders Germany. That country uses a nominal 230 V at 50 Hz, the same as Denmark, so an electrical rating that fits one side of the border fits the other.
Where capacitors are used in Denmark
Typical work in Denmark that needs capacitors:
- Split and window air conditioners
- Condensing units for walk-in cold rooms
- Fan coil unit and blower motors
- Commercial display fridges and freezers
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Denmark
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: Denmark uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Denmark that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.
Keeping capacitors reliable in Denmark
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Denmark lies in the northern hemisphere, where cooling demand usually peaks in July and August. Schedule inspections of capacitors for May or June, ahead of that peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Which standards apply to capacitors in Denmark
Two sets of rules apply to capacitors sold into Denmark: the product standard, IEC 60252-1 (AC motor capacitors), and the local one, CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Ordering capacitors for Denmark
Sea freight into Denmark normally clears through ports such as Aarhus, with onward delivery by road; urgent parts can travel by air.
The local currency is the Krone (DKK), so confirm the quotation currency and delivery terms before you order. The main languages are Danish, English, Faroese and German; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Denmark
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Denmark?
With a 230 V, 50 Hz supply, Denmark follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Which standards apply to capacitors in Denmark?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Denmark the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Denmark?
Cargo for Denmark usually arrives through Aarhus; tell us your preferred port or delivery address with your enquiry.
Which cities in Denmark can I order capacitors for?
Every listed city is covered. The largest are Copenhagen (1.2 million), Arhus (285,000), Odense (181,000), Aalborg (143,000) and Esbjerg (72,000). The country page lists the rest.
Do the neighbours of Denmark use the same mains supply?
Yes. Its only listed neighbour (Germany) runs on a nominal 230 V at 50 Hz, the same as Denmark, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Denmark?
Copenhagen keeps UTC+1, moving to UTC+2 while daylight saving applies. At 55.7° N there are about 17 h 32 min of daylight in June and about 7 h 01 min in December.
More Klima products for Denmark
- Klima Contactors in Denmark
- Klima Terminal Crimps in Denmark
- Klima Transformer for HVAC in Denmark
- Klima Drier Core 48-KL in Denmark
- Klima Thermostats in Denmark
- Klima PVC Tapes in Denmark