Klima Motor Start Capacitor 192-228 µF 250 V
Motor start capacitor for motors that need 192-228 µF at 250 V. A weak start capacitor shows up as a slow or failed start.
Klima Capacitors · Model KC-MS-192-228
About this capacitor
This 192-228 µF start capacitor has a 250 V rating and is one of 33 in its voltage group in the Klima range. Start capacitors are chosen by the µF range on the motor data and by the voltage class, so both appear in the product name.
The 192-228 µF figure is a range, not a single value: a start capacitor is specified by the window its capacitance may fall in. This window is 19 % wide and centres on about 210 µF, where the reactance is near 15.2 ? at 50 Hz and 12.6 ? at 60 Hz.
Specifications
| Specification | Value |
|---|---|
| Model | KC-MS-192-228 |
| Capacitance | 192-228 µF |
| Rated voltage | 250 VAC |
| Type | Start |
Where it fits
- Motors on 220-240 V supplies that specify a 250 V start capacitor
- Compressors that start only on the second or third attempt because the start capacitor is weak
- Larger air compressors that start against pressure
- Heavy-duty single-phase pumps and pressure sets
Fitting and checking
Never fit a start capacitor as a run capacitor, and never leave it in circuit after the motor has started. If the motor does not drop the capacitor out, a start capacitor in the 192-228 µF range will overheat and may split its case within minutes.
Compared with the other capacitors
The 116 models in Klima Capacitors differ mainly in capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 192-228 µF | 0.5 to 480 µF |
| Rated voltage | 250 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start | Single run, Dual run, Start, Start/run |
In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 189-227 µF 250 V (189-227 µF) and the next step up is Klima Motor Start Capacitor 200-240 µF 250 V (200-240 µF). Quote the model code KC-MS-192-228 when you enquire so that the right size is supplied.
Questions
What is the next range up or down from 192-228 µF?
Among the 250 V start capacitors the next range down is 189-227 µF and the next range up is 200-240 µF. Quote the range and the voltage class when you enquire.
What is the difference between 250 V and 330 V start capacitors?
Both are used on 220-240 V motors; the 330 V class has more voltage margin. A 330 V part can replace a 250 V one of the same µF range, but not the reverse. This 192-228 µF model is the 250 V class.
Why does my motor trip after the new start capacitor is fitted?
A tripped overload after fitting usually points to the wrong range, a relay that is not dropping out, or a wiring error rather than the capacitor. Check the µF range and the voltage against the motor data, confirm the relay or switch operates, and check that the wires are on the right terminals.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-192-228. For background reading, see the guide How to choose a run capacitor for an air conditioner.