Klima Motor Start Capacitor 200-240 µF 250 V
This Klima motor start capacitor has a capacity of 200-240 µF and a 250 V rating. The range midpoint is about 220 µF.
Klima Capacitors · Model KC-MS-200-240
About this capacitor
For a capacitor-start motor whose data calls for 200-240 µF, this 250 V Klima capacitor is the replacement. It carries starting current for a second or two, which is why it is a different part from a run capacitor even when the µF figure looks similar.
Start capacitance scales with the torque the motor must produce at standstill, so the µF range rises with motor size. At 220 µF, the middle of this window, the part is number 27 of 33 by capacitance among the 250 V start capacitors. A reading anywhere between 200 and 240 µF is a good capacitor; below 200 µF it has lost capacity.
Specifications
| Specification | Value |
|---|---|
| Model | KC-MS-200-240 |
| Capacitance | 200-240 µF |
| Rated voltage | 250 VAC |
| Type | Start |
Where it fits
- Commercial refrigeration compressors with a high starting torque requirement
- Replacements for a 250 V start capacitor of the same µF range
- Workshop machinery such as large saws and planers on single-phase supplies
- Heavy-duty single-phase pumps and pressure sets
Fitting and checking
Use the nearest range only if the motor maker allows it. A lower µF range reduces starting torque and a higher one raises starting current, which strains the start winding and the relay. If the exact 200-240 µF range is not to hand, ask for the nearest permitted range rather than guessing.
Compared with the other capacitors
Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 200-240 µF | 0.5 to 480 µF |
| Rated voltage | 250 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start | Single run, Dual run, Start, Start/run |
In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 192-228 µF 250 V (192-228 µF) and the next step up is Klima Motor Start Capacitor 200-250 µF 250 V (200-250 µF). Quote the model code KC-MS-200-240 when you enquire so that the right size is supplied.
Questions
If 200-240 µF is not right, which neighbouring ranges does Klima list?
Among the 250 V start capacitors the next range down is 192-228 µF and the next range up is 200-250 µF. Quote the range and the voltage class when you enquire.
What does the 200-240 µF range mean?
Start capacitors are specified by a window of capacitance rather than a single value. A 200-240 µF part should read anywhere from 200 to 240 µF, a window about 20 % wide. A reading below 200 µF means the capacitor has lost capacity and should be replaced.
Why does a start capacitor fail so often?
It works hard for a very short time. Heat from repeated starts, a supply that sags and prolongs starting, and a relay that holds the capacitor in circuit are the usual causes. A 200-240 µF part that has failed once should prompt a check of the relay or switch before the replacement goes in.