Klima Industries

Klima capacitors for Aruba

Home to about 106,000 people, Aruba sits in North America. Its capital is Oranjestad. Across Aruba the climate is hot and humid tropical, and conditions are similar from place to place. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Capacitors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Aruba for a quotation.

Capital
Oranjestad
Population
106,000
Area
193 km²
Time zone
UTC-4 all year
Climate
Hot and humid tropical
Supply
127 V, 60 Hz
Main ports
Oranjestad
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Aruba · Klima Capacitors overview

Capacitors and the climate in Aruba

In Aruba, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.

Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

The supply in Aruba is 127 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.

Where capacitors are needed in Aruba

Oranjestad is both the capital and the largest listed city, with about 30,000 people, so the capital is also the biggest single market. The table lists the largest cities in Aruba with the climate stress that wears capacitors fastest in each.

CityPeopleClimateWhat wears capacitors first
Oranjestad30,000hot and humid tropicalmoisture on terminals and corrosion
Noord24,000hot and humid tropicalmoisture on terminals and corrosion
Tanki Leendert22,000hot and humid tropicalmoisture on terminals and corrosion
Santa Cruz15,000hot and humid tropicalmoisture on terminals and corrosion

All 4 listed cities share a hot and humid tropical climate, so one stocking plan covers the whole country.

Time zone, sun and daylight in Aruba

Oranjestad keeps UTC-4 all year.

Sunlight at 12.5° N (Oranjestad): about 12 h 52 min of daylight in June, about 11 h 23 min in December, and a noon sun that reaches 79° in June and 54° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

Typical uses of capacitors in Aruba

Capacitors are most often specified in Aruba for:

  • Split and window air conditioners
  • Packaged rooftop units and ducted systems
  • Heat pump outdoor units
  • Fan coil unit and blower motors
  • Ventilation and exhaust fan motors

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round45 + 7.5440 / 370Dual run
Klima Motor Start Capacitor 64-77 µF 250 V64-77250Start
Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case216-259110 / 125Start
Klima CBB61 Start/Run Capacitor 4 µF 500 V AC4500Start/run
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting capacitors in Aruba

  • Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
  • Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
  • Confirm the supply first: Aruba uses 127 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Aruba that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Keeping capacitors reliable in Aruba

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.

A tropical climate keeps cooling demand steady through the year in Aruba, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Faults to watch for

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Standards and paperwork for capacitors in Aruba

Two sets of rules apply to capacitors sold into Aruba: the product standard, IEC 60252-1 (AC motor capacitors), and the local one, applicable national electrical-safety and import conformity rules (generally IEC-based). Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.

Ordering capacitors for Aruba

Cargo for Aruba usually arrives through Oranjestad; tell us your preferred port or delivery address with your enquiry.

The local currency is the Guilder (AWG), so confirm the quotation currency and delivery terms before you order. The main languages are Dutch, Papiamento, Spanish and English; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Aruba: common questions

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

What voltage should capacitors be rated for in Aruba?

Equipment in Aruba runs from 127 V at 60 Hz; make sure the capacitor you choose carries the right voltage and frequency rating for 60 Hz operation.

Which standards apply to capacitors in Aruba?

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Aruba the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are capacitors delivered to Aruba?

Sea freight into Aruba normally clears through ports such as Oranjestad, with onward delivery by road; urgent parts can travel by air.

Which cities in Aruba can I order capacitors for?

Every listed city is covered. The largest are Oranjestad (30,000), Noord (24,000), Tanki Leendert (22,000) and Santa Cruz (15,000). The country page lists the rest.

What local time and daylight should I plan for in Aruba?

Oranjestad keeps UTC-4 all year. At 12.5° N there are about 12 h 52 min of daylight in June and about 11 h 23 min in December.

More Klima products for Aruba

Capacitors in cities across Aruba