Klima Dual Run Capacitor 45+10 µF 440/370 V, Round
Dual run capacitor with 45+10 µF capacity and a 440/370 V rating, in a round case. The sizes either side in this style are 45+7.5 and 50+5 µF.
Klima Capacitors · Model KC-DR-45-10
About this capacitor
This Klima dual run capacitor combines a 45 µF section and a 10 µF section in one round can. The larger section serves the compressor motor and the smaller one serves the fan motor, so a single part replaces two separate capacitors on the outdoor unit. It is dual-rated 440/370 V for 50/60 Hz supplies.
Each section has its own tolerance window. For a ±5 % part the 45 µF section should measure between 42.75 and 47.25 µF and the 10 µF section between 9.5 and 10.5 µF; for ±10 % the windows are 40.5 to 49.5 µF and 9 to 11 µF.
Specifications
| Specification | Value |
|---|---|
| Model | KC-DR-45-10 |
| Capacitance | 45 + 10 µF |
| Rated voltage | 440 / 370 VAC |
| Type | Dual run |
| Case | Round |
| Frequency | 50/60 Hz |
Where it fits
- Equipment whose old dual capacitor is marked 370 V or 440 V, since this part carries both ratings
- Ducted split systems whose outdoor unit data plate lists a dual run capacitor
- Replacing a swollen or leaking dual capacitor on an outdoor condensing unit
- Condensing units for cold rooms and commercial refrigeration with single-phase motors
Fitting and checking
Check the equipment data plate for the 45+10 µF pairing and the voltage class before fitting. The case has to fit the bracket and the space under the cover, so compare diameter and height with the old part. After fitting, run the unit and confirm that both the compressor and the fan start cleanly.
Compared with the other capacitors
Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 45 + 10 µF | 0.5 to 480 µF |
| Rated voltage | 440 / 370 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Dual run | Single run, Dual run, Start, Start/run |
| Case | Round | Round, Oval, Oval aluminium, Round phenolic |
In the KC-DR series, the next step down by capacitance is Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round (45 + 7.5 µF) and the next step up is Klima Dual Run Capacitor 50+5 µF 440/370 V, Round (50 + 5 µF). Quote the model code KC-DR-45-10 when you enquire so that the right size is supplied.
Questions
If 45+10 µF is not right, which neighbouring pairings does Klima list?
Within the 440/370 V dual run capacitors the next pairing down is 45+7.5 µF and the next pairing up is 50+5 µF. Both values and the dual 440/370 V rating are matched in the enquiry.
What if only one section has failed?
Replace the whole can. The sections share one case and one construction, and a part with one section out of tolerance has aged as a whole. A new 45+10 µF can restores both the compressor and the fan sections at once.
What should I check after fitting the new 45+10 µF can?
Run the unit and watch both motors: the compressor should start without a long hum and the fan should reach full speed at once. Compare the compressor running current with the data plate figure; a current well above it means something other than the capacitor, such as the compressor itself or the supply, needs attention.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-DR-45-10. For background reading, see the guide How to choose a run capacitor for an air conditioner.