Klima Dual Run Capacitor 60+7.5 µF 440/370 V, Round

Dual run capacitor, 60+7.5 µF, rated 440/370 V, round case. It is the 10th of 10 dual sizes, from 10 to 60 µF.

Klima Capacitors · Model KC-DR-60-7.5

About this capacitor

Klima lists this 60+7.5 µF dual run capacitor for 50/60 Hz service. Because the compressor and fan sections share one can and one mounting, it is simpler to fit than two separate capacitors and leaves fewer connections to go wrong.

At 50 Hz the 60 µF section has a reactance of about 53.1 ? and the 7.5 µF section about 424 ?. On a 230 V supply that is roughly 4.34 A and 0.54 A of capacitor current, so the compressor section carries about 8 times the current of the fan section.

Specifications

SpecificationValue
ModelKC-DR-60-7.5
Capacitance60 + 7.5 µF
Rated voltage440 / 370 VAC
TypeDual run
CaseRound
Frequency50/60 Hz

Where it fits

  • Replacements where the old can was a round 440/370 V part with the same pair of µF values
  • Units that start slowly or trip the compressor overload in summer because one section has weakened
  • Split and packaged air conditioners with a single-phase compressor and a permanent-split-capacitor condenser fan
  • Ducted split systems whose outdoor unit data plate lists a dual run capacitor

Fitting and checking

Measure each section of the old can before ordering: C to HERM should be near 60 µF and C to FAN near 7.5 µF. A low reading on either section means the can is finished. Fit the 60+7.5 µF replacement in the same bracket, tighten it so the case cannot rotate, and check that every connector is tight.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance60 + 7.5 µF0.5 to 480 µF
Rated voltage440 / 370 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeDual runSingle run, Dual run, Start, Start/run
CaseRoundRound, Oval, Oval aluminium, Round phenolic

In the KC-DR series, this is the largest model by capacitance; the next step down is Klima Dual Run Capacitor 55+7.5 µF 440/370 V, Round (55 + 7.5 µF). Quote the model code KC-DR-60-7.5 when you enquire so that the right size is supplied.

Questions

Which sizes sit either side of the 60+7.5 µF model?

60+7.5 µF is the largest pairing among the 440/370 V dual run capacitors, and the next one down is 55+7.5 µF. Both values and the dual 440/370 V rating are matched in the enquiry.

Why is it rated 440/370 V?

The dual rating lets one part replace cans marked 370 V or 440 V. The voltage across a run capacitor in service is higher than the supply, so 230 V equipment still specifies these ratings. A higher rating is acceptable when replacing; a lower one is not.

Why does the outdoor fan stop while the compressor still runs?

The fan section is the small one, 7.5 µF here, and it often weakens first. A fan that stops, spins slowly or needs a push while the compressor still starts usually points to that section; a reading below about 6.75 µF on a capacitance meter confirms it. Replace the whole 60+7.5 µF can rather than the one section.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-DR-60-7.5. For background reading, see the guide How to choose a run capacitor for an air conditioner.