Klima Motor Start Capacitor 80-96 µF 250 V
Motor start capacitor with 80-96 µF capacity and a 250 V rating. Match the µF range and voltage class to the old part.
Klima Capacitors · Model KC-MS-80-96
About this capacitor
80-96 µF at 250 V: the two numbers that identify this Klima start capacitor. It suits motors that use a start relay or switch to take the capacitor out of circuit after the motor has run up to speed.
The 80-96 µF figure is a range, not a single value: a start capacitor is specified by the window its capacitance may fall in. This window is 20 % wide and centres on about 88 µF, where the reactance is near 36.2 ? at 50 Hz and 30.1 ? at 60 Hz.
Specifications
| Specification | Value |
|---|---|
| Model | KC-MS-80-96 |
| Capacitance | 80-96 µF |
| Rated voltage | 250 VAC |
| Type | Start |
Where it fits
- Motors on 220-240 V supplies that specify a 250 V start capacitor
- Pump motors that need several attempts to start on a weak supply
- Replacement where the motor hums, draws high current and will not accelerate
- Single-phase compressors in air-conditioning and refrigeration plant that use a start capacitor and relay
Fitting and checking
A start capacitor lives a harsh duty cycle, so look for the reason behind a failure. A worn start relay or switch that leaves the capacitor in circuit, repeated restarts after a trip and a supply that sags during starting all shorten its life. Fit the 80-96 µF replacement only after those causes are ruled out.
Compared with the other capacitors
This model is one of 116 in Klima Capacitors; what changes from one to the next is capacitance, rated voltage and type.
| Specification | This model | Across the range |
|---|---|---|
| Capacitance | 80-96 µF | 0.5 to 480 µF |
| Rated voltage | 250 VAC | 110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC |
| Type | Start | Single run, Dual run, Start, Start/run |
In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 72-86 µF 250 V (72-86 µF) and the next step up is Klima Motor Start Capacitor 80-100 µF 250 V (80-100 µF). Quote the model code KC-MS-80-96 when you enquire so that the right size is supplied.
Questions
What is the next range up or down from 80-96 µF?
Among the 250 V start capacitors the next range down is 72-86 µF and the next range up is 80-100 µF. Quote the range and the voltage class when you enquire.
How long can a start capacitor stay in circuit?
Only for a second or two at each start. The motor's relay, centrifugal switch or electronic switch should take it out of circuit as the motor reaches speed. If an 80-96 µF capacitor is warm to the touch after a normal start, check the switching device before the capacitor.
Why does a start capacitor fail so often?
It works hard for a very short time. Heat from repeated starts, a supply that sags and prolongs starting, and a relay that holds the capacitor in circuit are the usual causes. An 80-96 µF part that has failed once should prompt a check of the relay or switch before the replacement goes in.
Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-80-96. For background reading, see the guide How to choose a run capacitor for an air conditioner.